SIMULTANEOUS DETERMINATION OF ZN, CD, PB, AND CU IN URINE OF PATIENTS WITH BLACKFOOT DISEASE USING ANODIC-STRIPPING VOLTAMMETRY

被引:16
作者
PAN, TC
HORNG, CJ
LIN, SR
LIN, TH
HUANG, CW
机构
[1] CHUNG YUAN CHRISTIAN UNIV,INST CHEM,CHUNGLI 320,TAIWAN
[2] KAOHSIUNG MED COLL,SCH TECHNOL MED SCI,KAOHSIUNG 807,TAIWAN
关键词
BLACKFOOT DISEASE; DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY; ZINC; CADMIUM; LEAD; COPPER; URINE SPECIMENS;
D O I
10.1007/BF02785308
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Blackfoot disease (BFD) is an endemic peripheral vascular disorder resulting in gangrene of the lower extremities, especially the feet, among residents in a limited area on the southwest coast of Taiwan. In the present study, the concentrations of zinc, cadmium, lead, and copper in urine of BFD patients with matched normal controls are investigated by differential pulse anodic stripping voltammetry (DPASV) on a hanging mercury drop electrode (HMDE). The analytical results indicate that urinary Copper, cadmium, and lead of the BFD patients are significantly higher than those of the controls. In addition, the patients showed a significantly lower concentration of zinc in the urine than the normal controls. The possible connection of these elements with the etiology of the disease is discussed.
引用
收藏
页码:233 / 241
页数:9
相关论文
共 16 条
[1]   MULTIELEMENT DETERMINATION IN BIOLOGICAL-MATERIALS BY DIFFERENTIAL PULSE VOLTAMMETRY [J].
ADELOJU, SB ;
BOND, AM ;
BRIGGS, MH .
ANALYTICAL CHEMISTRY, 1985, 57 (07) :1386-1390
[2]  
BLUST R, 1985, ATOM SPECTROSC, V6, P163
[3]  
BOND AM, 1984, ANAL CHIM ACTA, V162, P389, DOI 10.1016/S0003-2670(00)84263-4
[4]   ATHEROGENICITY AND CARCINOGENICITY OF HIGH-ARSENIC ARTESIAN WELL WATER - MULTIPLE RISK-FACTORS AND RELATED MALIGNANT NEOPLASMS OF BLACKFOOT DISEASE [J].
CHEN, CJ ;
WU, MM ;
LEE, SS ;
WANG, JD ;
CHENG, SH ;
WU, HY .
ARTERIOSCLEROSIS, 1988, 8 (05) :452-460
[5]   ANALYTICAL APPLICATIONS OF PULSED VOLTAMMETRIC STRIPPING AT THIN-FILM MERCURY ELECTRODES [J].
COPELAND, TR ;
CHRISTIE, JH ;
OSTERYOUNG, RA ;
SKOGERBOE, RK .
ANALYTICAL CHEMISTRY, 1973, 45 (13) :2171-2174
[6]   DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY AS A RAPID SCREENING TECHNIQUE FOR HEAVY-METAL INTOXICATIONS [J].
FRANKE, JP ;
DEZEEUW, RA .
ARCHIVES OF TOXICOLOGY, 1976, 37 (01) :47-55
[7]   RAPID HIGH-PERFORMANCE ANALYTICAL PROCEDURE WITH SIMULTANEOUS VOLTAMMETRIC DETERMINATION OF TOXIC TRACE-METALS IN URINE [J].
GOLIMOWSKI, J ;
VALENTA, P ;
STOEPPLER, M ;
NURNBERG, HW .
TALANTA, 1979, 26 (08) :649-656
[8]   USE OF MERCURY DROP ELECTRODE METHODS FOR DIRECT EVALUATION OF MINUTE AMOUNTS OF LEAD IN URINE [J].
KEMULA, W ;
KUBLIK, Z .
NATURE, 1961, 189 (475) :57-&
[9]   ARSENIC, SELENIUM, AND ZINC IN PATIENTS WITH BLACKFOOT DISEASE [J].
LIN, SM ;
YANG, MH .
BIOLOGICAL TRACE ELEMENT RESEARCH, 1988, 15 :213-221
[10]  
LIN SM, 1985, J ENV PROTECT SOC, V8, P31