NITRO CONTAINING L-ARGININE ANALOGS INTERFERE WITH ASSAYS FOR NITRATE AND NITRITE

被引:65
作者
GREENBERG, SS
XIE, JM
SPITZER, JJ
WANG, JF
LANCASTER, J
GRISHAM, MB
POWERS, DR
GILES, TD
机构
[1] LOUISIANA STATE UNIV,HLTH SCI CTR,DEPT PHYSIOL,NEW ORLEANS,LA 70112
[2] LOUISIANA STATE UNIV,HLTH SCI CTR,DEPT OBSTET & GYNECOL,NEW ORLEANS,LA 70112
[3] LOUISIANA STATE UNIV,HLTH SCI CTR,DEPT PHYSIOL & BIOPHYS,SHREVEPORT,LA 71130
关键词
NITRIC OXIDE; NITRITE ANION; REACTIVE NITROGEN INTERMEDIATES; AMINOGUANIDINE; CHEMILUMINESCENCE ASSAY; GREISS ASSAY; NITRATE ASSAY;
D O I
10.1016/0024-3205(95)02181-H
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
We evaluated the effect of in vivo and in vitro administration of nitro-containing and nitro-deficient L-arginine-derived nitric oxide (NO) synthase inhibitors on the measurement of NO in plasma, urine and HEPES buffered physiologic salt solution (PSS) by ozone chemiluminescence and by the modified Griess reaction. In vivo administration of 1, 5, 25, 40 or 50 mg/kg of NG-nitro-L-or D-arginine methyl ester (LNAME, DNAME), NG-nitro-L-arginine (LNA) or aminoguanidine (AG) to rats and mice increased NO in urine and plasma as determined by chemiluminescence using 2.3% vanadium chloride in 2N HCl at 100 degrees C as the redox reagent. In vivo administration of 1 and 10 mg/kg/day of N-5-imino-ethyl-L-ornithine (LNIO) or 3 amino-1,2,4 triazine (AT) reduced plasma and urine NO. Addition of LNAME, DNAME and LNA (100 nM to 1 mM) to the redox solution produced a concentration response curve for NO in the chemiluminescence assay similar to that produced by standard solutions of sodium nitrite and nitrate. LNMMA produced a small NO signal but only at concentrations equal to or exceeding 0.1 mM. LNIO, AT and AG did not give any NO signal even at concentrations exceeding 1 mM. Conversion of plasma or urine nitrate to nitrite with cadmium gave elevated values of plasma nitrite by the Greiss assay when LNAME or LNA was the NO synthase inhibitor. We conclude that in vivo and in vitro use of LNAME and LNA and in vivo use of high doses of aminoguanidine interfere with the assay of NO2- and NO3- with the modified Griess reaction and with chemiluminescence. We suggest that LNAME and LNA not be used in vivo or in vitro when total RNI is measured with these assays.
引用
收藏
页码:1949 / 1961
页数:13
相关论文
共 48 条
[1]  
ARCHER MC, 1983, IARC PUBL, P245
[2]   MEASUREMENT OF NITRIC-OXIDE IN BIOLOGICAL MODELS [J].
ARCHER, S .
FASEB JOURNAL, 1993, 7 (02) :349-360
[3]   FLUOROMETRIC-DETERMINATION OF SUB-NANOGRAM LEVELS OF NITRITE USING 5-AMINOFLUORESCEIN [J].
AXELROD, HD ;
ENGEL, NA .
ANALYTICAL CHEMISTRY, 1975, 47 (06) :922-924
[4]   NANOGRAM NITRITE AND NITRATE DETERMINATION IN ENVIRONMENTAL AND BIOLOGICAL-MATERIALS BY VANADIUM(III) REDUCTION WITH CHEMI-LUMINESCENCE DETECTION [J].
BRAMAN, RS ;
HENDRIX, SA .
ANALYTICAL CHEMISTRY, 1989, 61 (24) :2715-2718
[5]  
BREDT DS, 1995, ANNU REV BIOCHEM, V63, P175
[6]   N(G)-NITRO L-ARGININE METHYL-ESTER AND OTHER ALKYL ESTERS OF ARGININE ARE MUSCARINIC RECEPTOR ANTAGONISTS [J].
BUXTON, ILO ;
CHEEK, DJ ;
ECKMAN, D ;
WESTFALL, DP ;
SANDERS, KM ;
KEEF, KD .
CIRCULATION RESEARCH, 1993, 72 (02) :387-395
[7]  
CORTAS NK, 1990, CLIN CHEM, V36, P1440
[8]  
DAVIS CE, 1985, J ASSOC OFF ANA CHEM, V68, P485
[9]   NITRIC-OXIDE INHIBITION CAUSES INTRAUTERINE GROWTH-RETARDATION AND HINDLIMB DISRUPTIONS IN RATS [J].
DIKET, AL ;
PIERCE, MR ;
MUNSHI, UK ;
VOELKER, CA ;
ELOBYCHILDRESS, S ;
GREENBERG, SS ;
ZHANG, XJ ;
CLARK, DA ;
MILLER, MJS .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (05) :1243-1250
[10]  
Foerstermann Ulrich, 1994, Hypertension (Dallas), V23, P1121