COMPARATIVE-ASSESSMENT OF 2 ALGORITHMS FOR CALIBRATING STEREOPHOTOGRAMMETRIC SYSTEMS

被引:17
作者
GAZZANI, F
机构
[1] Istituto Superiore di Sanita, Lab. Ingegneria Biomedica, 299 Roma, V. le Regina Elena
关键词
Algorithms - Calibration - Camera lenses - Cameras - Computer simulation;
D O I
10.1016/0021-9290(93)90095-V
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this paper, a comparison is carried out between two photogrammetric algorithms aimed at camera calibration and three-dimensional target point reconstruction by 'absolute' distributions of control points; the first is Marzan and Karara's DLT, the second is CESNO, by the author, an algorithm quite close to Hatze's modified DLT (MDLT). The comparative assessment is especially aimed at testing the capability of the two methods to produce good results when calibration data are to be extrapolated beyond the space spanned by the control distribution. The assessment was carried out not by a real stereophotogrammetric system, but by the computer simulation of a two-camera set-up. Various combinations of internal camera parameters, such as the scaled principal distances, were tried out. As for the magnitude of the simulated non-linear lens distortion, three configurations were used which produced 'low', 'medium' and 'strong' distortion. The influence of decreasing the number of control (calibration) points on the accuracy performance of the two algorithms was also investigated. The results show the superiority of CESNO, especially with medium or strong lens distortion, or when the two camera principal distances sensibly differ.
引用
收藏
页码:1449 / 1454
页数:6
相关论文
共 14 条
[1]  
ABDELAZIZ YI, 1971, P ASP UI S CLOS RANG, P1
[2]  
ALEM NM, 1978, 6TH P NEW ENGL BIOEN, P202
[3]   3-DIMENSIONAL CINEMATOGRAPHY WITH CONTROL OBJECT OF UNKNOWN SHAPE [J].
DAPENA, J ;
HARMAN, EA ;
MILLER, JA .
JOURNAL OF BIOMECHANICS, 1982, 15 (01) :11-19
[4]   PERFORMANCE OF A 7-PARAMETER DLT METHOD FOR THE CALIBRATION OF STEREOPHOTOGRAMMETRIC SYSTEMS USING 1-D TRANSDUCERS [J].
GAZZANI, F .
JOURNAL OF BIOMEDICAL ENGINEERING, 1992, 14 (06) :476-482
[5]  
GAZZANI F, 1993, IN PRESS HUMAN MVMT
[6]  
Ghosh S.K., 1979, ANAL PHOTOGRAMMETRY
[7]   HIGH-PRECISION 3-DIMENSIONAL PHOTOGRAMMETRIC CALIBRATION AND OBJECT SPACE RECONSTRUCTION USING A MODIFIED DLT-APPROACH [J].
HATZE, H .
JOURNAL OF BIOMECHANICS, 1988, 21 (07) :533-538
[8]  
MARZAN GT, 1975, S CLOSE RANGE PHOTOG, P420
[9]   A TECHNIQUE FOR OBTAINING SPATIAL KINEMATIC PARAMETERS OF SEGMENTS OF BIOMECHANICAL SYSTEMS FROM CINEMATOGRAPHIC DATA [J].
MILLER, NR ;
SHAPIRO, R ;
MCLAUGHLIN, TM .
JOURNAL OF BIOMECHANICS, 1980, 13 (07) :535-+
[10]   DIRECT LINEAR TRANSFORMATION METHOD FOR 3-DIMENSIONAL CINEMATOGRAPHY [J].
SHAPIRO, R .
RESEARCH QUARTERLY, 1978, 49 (02) :197-205