Coronary artery flow monitoring: The value of intravascular Doppler for detection of complications after interventions

被引:3
作者
Anderson, HV [1 ]
Kirkeeide, RL [1 ]
Willerson, JT [1 ]
Smalling, RW [1 ]
Schroth, G [1 ]
机构
[1] HERMANN HOSP,HOUSTON,TX
关键词
Doppler ultrasound; coronary flow; cyclic flow variations; coronary interventions; coronary angioplasty;
D O I
10.1093/eurheartj/16.suppl_L.93
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Ultrasound transducer-tipped guidewires can be used for coronary interventions and they permit the monitoring of coronary flow before, during, and after the interventions. The flow signal contains valuable information regarding the quality and stability of the final result. Restoration of typical phasic flow patterns with diastolic predominance is one guide to final result. Monitoring the trend in average velocity over several minutes after completion of the procedure can detect subtle alterations in pow that may presage abrupt closure. These flow alterations might also help predict active plaques with heavy thrombus involvement that may undergo recurrence in the weeks and months after successful procedures.
引用
收藏
页码:93 / 96
页数:4
相关论文
共 20 条
[1]   CYCLIC CORONARY-ARTERY FLOW IN DOGS AFTER CORONARY ANGIOPLASTY [J].
ANDERSON, HV ;
YAO, SK ;
MURPHREE, SS ;
BUJA, LM ;
MCNATT, JM ;
WILLERSON, JT .
CORONARY ARTERY DISEASE, 1990, 1 (06) :717-723
[2]   CYCLIC FLOW VARIATIONS AFTER CORONARY ANGIOPLASTY IN HUMANS - CLINICAL AND ANGIOGRAPHIC CHARACTERISTICS AND ELIMINATION WITH 7E3 MONOCLONAL ANTIPLATELET ANTIBODY [J].
ANDERSON, HV ;
KIRKEEIDE, RL ;
KRISHNASWAMI, A ;
WEIGELT, LA ;
REVANA, M ;
WEISMAN, HF ;
WILLERSON, JT .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (05) :1031-1037
[3]  
ANDERSON HV, 1991, COMPLICATIONS CORONA, P79
[4]  
ANDERSON HV, 1994, THROMBOSIS HEMORRHAG, P385
[5]  
ANDERSON HV, 1995, J AM COLL CARDIOL, pA225
[6]   CORONARY ANGIOPLASTY FOR UNSTABLE ANGINA [J].
DEFEYTER, PJ .
AMERICAN HEART JOURNAL, 1989, 118 (04) :860-868
[7]   ACUTE CORONARY-ARTERY OCCLUSION DURING AND AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - FREQUENCY, PREDICTION, CLINICAL COURSE, MANAGEMENT, AND FOLLOW-UP [J].
DEFEYTER, PJ ;
VANDENBRAND, M ;
JAARMAN, G ;
VANDOMBURG, R ;
SERRUYS, PW ;
SURYAPRANATA, H .
CIRCULATION, 1991, 83 (03) :927-936
[8]   INCIDENCE AND CONSEQUENCES OF PERIPROCEDURAL OCCLUSION - THE 1985-1986 NATIONAL HEART, LUNG, AND BLOOD INSTITUTE PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY REGISTRY [J].
DETRE, KM ;
HOLMES, DR ;
HOLUBKOV, R ;
COWLEY, MJ ;
BOURASSA, MG ;
FAXON, DP ;
DORROS, GR ;
BENTIVOGLIO, LG ;
KENT, KM ;
MYLER, RK .
CIRCULATION, 1990, 82 (03) :739-750
[9]  
GOLD HK, 1991, CIRCULATION, V83, P26
[10]   USEFULNESS OF QUANTITATIVE AND QUALITATIVE ANGIOGRAPHIC LESION MORPHOLOGY, AND CLINICAL CHARACTERISTICS IN PREDICTING MAJOR ADVERSE CARDIAC EVENTS DURING AND AFTER NATIVE CORONARY BALLOON ANGIOPLASTY [J].
HERMANS, WRM ;
FOLEY, DP ;
RENSING, BJ ;
RUTSCH, W ;
HEYNDRICKX, GR ;
DANCHIN, N ;
MAST, G ;
HANET, C ;
LABLANCHE, JM ;
RAFFLENBEUL, W ;
UEBIS, R ;
BALCON, R ;
DEFEYTER, PJ ;
SERRUYS, PW .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (01) :14-20