EFFECT OF INTRACORONARY ULTRASOUND IMAGING ON CLINICAL DECISION-MAKING

被引:42
作者
LEE, DY [1 ]
EIGLER, N [1 ]
LUO, H [1 ]
NISHIOKA, T [1 ]
TABAK, SW [1 ]
FORRESTER, JS [1 ]
SIEGEL, RJ [1 ]
机构
[1] CEDARS SINAI MED CTR,DIV CARDIOL,LOS ANGELES,CA 90048
关键词
D O I
10.1016/0002-8703(95)90387-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to determine the effect of intravascular ultrasound (IVUS) imaging on decision making in the performance of coronary interventions, One hundred lesions were assessed in 87 patients undergoing balloon or laser angioplasty, atherectomy, stent placement, and additional diagnostic examination. Angiographically acceptable results were deemed inadequate by IVUS in 29% of angioplasties and 30% of stent deployments, and planned procedures subsequently were altered. Abnormalities commonly identified by IVUS and not by angiography were 13 coronary dissections after the procedure and 14 significant stenoses in apparently normal angiograms and significant stenoses were excluded in 7 patients with ambiguous angiograms. The apparent contribution of coronary IVUS imaging led to its significantly increased use over a 1-year period, as coronary interventional decisions on the basis of IVUS findings increased from 4 (17%) of 19 to 60 (74%) of 81. These data suggest that IVUS is a useful adjunct to angiography in selected patients for (1) identification or exclusion of dissection, (2) assessment of the adequacy of balloon angioplasty, (3) identification or exclusion of thrombus, (4) measurement of the depth of tissue removal, (5) determination of stent sire and the result of stent deployment, and (6) assessment of the severity of stenoses, especially at ostial sites.
引用
收藏
页码:1084 / 1093
页数:10
相关论文
共 33 条
[1]   CORONARY-ARTERY NARROWING IN CORONARY HEART-DISEASE - COMPARISON OF CINEANGIOGRAPHIC AND NECROPSY FINDINGS [J].
ARNETT, EN ;
ISNER, JM ;
REDWOOD, DR ;
KENT, KM ;
BAKER, WP ;
ACKERSTEIN, H ;
ROBERTS, WC .
ANNALS OF INTERNAL MEDICINE, 1979, 91 (03) :350-356
[2]  
Bom N, 1989, Int J Card Imaging, V4, P79, DOI 10.1007/BF01745137
[3]  
Chae J S, 1992, J Am Soc Echocardiogr, V5, P577
[4]   INTRACORONARY ULTRASOUND EVALUATION OF INTERVENTIONAL TECHNOLOGIES [J].
DAVIDSON, CJ ;
SHEIKH, KH ;
KISSLO, KB ;
PHILLIPS, HR ;
PETER, RH ;
BEHAR, VS ;
KONG, Y ;
KRUCOFF, M ;
OHMAN, EM ;
TCHENG, JE ;
STACK, RS .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (13) :1305-1309
[5]  
GARRETT KN, 1991, CATHET CARDIOVASC DI, V23, P74
[6]  
GRONDIN CM, 1974, CIRCULATION, V49, P703
[7]   ARTERIAL-WALL CHARACTERISTICS DETERMINED BY INTRAVASCULAR ULTRASOUND IMAGING - AN INVITRO STUDY [J].
GUSSENHOVEN, EJ ;
ESSED, CE ;
LANCEE, CT ;
MASTIK, F ;
FRIETMAN, P ;
VANEGMOND, FC ;
REIBER, J ;
BOSCH, H ;
VANURK, H ;
ROELANDT, J ;
BOM, N .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (04) :947-952
[8]   INTRACORONARY ULTRASOUND IMAGING - CORRELATION OF PLAQUE MORPHOLOGY WITH ANGIOGRAPHY, CLINICAL SYNDROME AND PROCEDURAL RESULTS IN PATIENTS UNDERGOING CORONARY ANGIOPLASTY [J].
HODGSON, JM ;
REDDY, KG ;
SUNEJA, R ;
NAIR, RN ;
LESNEFSKY, EJ ;
SHEEHAN, HM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (01) :35-44
[9]   INTRAVASCULAR ULTRASOUND IMAGING [J].
HONYE, J ;
MAHON, DJ ;
TOBIS, JM .
TRENDS IN CARDIOVASCULAR MEDICINE, 1991, 1 (07) :305-311
[10]   MORPHOLOGICAL EFFECTS OF CORONARY BALLOON ANGIOPLASTY INVIVO ASSESSED BY INTRAVASCULAR ULTRASOUND IMAGING [J].
HONYE, J ;
MAHON, DJ ;
JAIN, A ;
WHITE, CJ ;
RAMEE, SR ;
WALLIS, JB ;
ALZARKA, A ;
TOBIS, JM .
CIRCULATION, 1992, 85 (03) :1012-1025