PLATINIZED CARBON ULTRAMICROELECTRODES AS GLUCOSE BIOSENSORS

被引:18
作者
REYNOLDS, ER
YACYNYCH, AM
机构
关键词
GLUCOSE; BIOSENSOR; MICROELECTRODE; PLATINIZATION;
D O I
10.1002/elan.1140050506
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Miniaturized glucose biosensors were constructed by all-chemical means from disk-shaped carbon ultramicroelectrodes (UMEs) (diameter = 8 mum). These ultramicrobiosensors (UMBs) are capable of direct measurement of glucose in the presence of interfering species. Carbon UMEs were partially platinized by the electrochemical reduction of a platinum (IV) complex. Platinization of the carbon UMEs gave an increased current response to hydrogen peroxide and allowed the modified electrode to be operated at a lower oxidative potential. Glucose oxidase (E.C. 1.1.3.4.) was immobilized either by glutaraldehyde cross-linking or by direct covalent attachment to the electrode surface using carbodiimide. Response time (100% response) was 15-45 seconds. Response was linear over the range of 3-7 mM glucose. An electropolymerized film of poly(1,3-diaminobenzene) was used to prevent interfering species.
引用
收藏
页码:405 / 411
页数:7
相关论文
共 26 条
[1]   INTRACELLULAR ANALYSIS WITH AN IMMOBILIZED-ENZYME GLUCOSE ELECTRODE HAVING A 2-MU-M DIAMETER AND SUBSECOND RESPONSE-TIMES [J].
ABE, T ;
LAU, YY ;
EWING, AG .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (19) :7421-7423
[2]   THE EFFECT OF PH ON SOME OUTER-SPHERE ELECTRODE-REACTIONS AT CARBON ELECTRODES [J].
DEAKIN, MR ;
STUTTS, KJ ;
WIGHTMAN, RM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 182 (01) :113-122
[3]   SIMPLE AND RELIABLE FABRICATION OF CARBON-FIBER ULTRAMICROELECTRODES [J].
FERNANDEZ, AIS ;
CALZON, JAG ;
GARCIA, AC ;
BLANCO, PT .
ELECTROANALYSIS, 1991, 3 (4-5) :413-417
[4]   ELECTROPOLYMERIZED FILMS TO PREVENT INTERFERENCES AND ELECTRODE FOULING IN BIOSENSORS [J].
GEISE, RJ ;
ADAMS, JM ;
BARONE, NJ ;
YACYNYCH, AM .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (02) :151-160
[5]  
GEISE RJ, 1989, CHEM SENSORS MICROIN, P65
[6]   ELECTROCHEMICAL PLATINIZATION OF RETICULATED VITREOUS CARBON ELECTRODES TO INCREASE BIOSENSOR RESPONSE [J].
HEIDER, GH ;
SASSO, SV ;
HUANG, KM ;
YACYNYCH, AM ;
WIECK, HJ .
ANALYTICAL CHEMISTRY, 1990, 62 (11) :1106-1110
[7]  
IKARIYAMA Y, 1987, ANAL LETT, V20, P1407
[8]  
IKARIYAMA Y, 1987, ANAL LETT, V20, P1791
[9]   SURFACE CONTROL OF PLATINIZED PLATINUM AS A TRANSDUCER MATRIX FOR MICRO-ENZYME ELECTRODES [J].
IKARIYAMA, Y ;
YAMAUCHI, S ;
YUKIASHI, T ;
USHIODA, H .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 251 (02) :267-274
[10]  
KAWAGOE JL, 1991, ANAL CHEM, V63, P961