EFFECT OF INTRA-UTERINE CONTRACEPTIVE DEVICE ON UTERINE HEMOSTASIS - MORPHOLOGICAL-STUDY

被引:17
作者
APARICIO, SR
BRADBURY, K
BIRD, CC
FOLEY, ME
JENKINS, DM
CLAYTON, JK
SCOTT, JS
RAJAH, SM
MCNICOL, GP
机构
[1] REG BLOOD TRANSFUS SERV,LEEDS,ENGLAND
[2] UNIV LEEDS,GEN INFIRM,DEPT MED,LEEDS LS1 3EX,W YORKSHIRE,ENGLAND
[3] UNIV LEEDS,LEEDS MATERN HOSP,DEPT OBSTET & GYNECOL,LEEDS LS2 9NG,W YORKSHIRE,ENGLAND
来源
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY | 1979年 / 86卷 / 04期
关键词
D O I
10.1111/j.1471-0528.1979.tb11262.x
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
The effect of the intrauterine contraceptive device (IUCD) on uterine haemostasis was studied at various stages of the menstrual cycle in a series of 46 patients by light‐ and electron‐microscopy and by following the distribution of an infusion of 51Cr‐labelled autologous platelets. The endometrium in contact with the IUCD in the majority of cases showed grooving with atrophy and mild chronic inflammation in the surrounding tissues. The adjacent stroma also showed increased vascularity and occasional foci of haemorrhage but the increased blood loss associated with the presence of the IUCD could not be attributed to mechanical erosion or disruption of stromal blood vessels by the device. During menstruation the presence of an IUCD does not appear to inhibit the formation of fibrin/platelet thrombi although both in control and IUCD patients there was a striking paucity of platelet/fibrin thrombi in circumstances where their formation should be enhanced. In contrast to other workers we have not observed that gaps or breaks in the endothelial lining of endometrial blood vessels occur with any greater frequency in patients fitted with an IUCD. The principal mechanism by which uterine haemostasis is achieved remains to be established. Copyright © 1979, Wiley Blackwell. All rights reserved
引用
收藏
页码:314 / 324
页数:11
相关论文
共 18 条
[1]  
ANCLA M, 1967, LAB INVEST, V17, P61
[2]   ENDOMETRIAL RESPONSE TO INTRAUTERINE DEVICE [J].
BONNEY, WA ;
GLASSER, SR ;
CLEWE, TH ;
NOYES, RW ;
COOPER, CL .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1966, 96 (01) :101-&
[3]  
Buckle A E, 1966, J Obstet Gynaecol Br Commonw, V73, P993
[4]   ULTRASTRUCTURAL STUDIES ON ENDOMETRIUM OF WOMEN WEARING TCU-200 INTRAUTERINE-DEVICES BY MEANS OF TRANSMISSION AND SCANNING ELECTRON-MICROSCOPY AND X-RAY DISPERSIVE ANALYSIS [J].
GONZALEZANGULO, A ;
AZNARRAMOS, R .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1976, 125 (02) :170-179
[5]  
GONZALEZANGULO A, 1973, J REPROD MED, V10, P44
[6]   EFFECT OF INTRAUTERINE STAINLESS STEEL RING ON ENDOMETRIAL STRUCTURE AND FUNCTION [J].
HALL, HH ;
SEDLIS, A ;
CHABON, I ;
STONE, ML .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1965, 93 (07) :1031-&
[7]   VASCULAR DEFECTS IN HUMAN ENDOMETRIUM CAUSED BY INTRAUTERINE CONTRACEPTIVE DEVICES - ELECTRON-MICROSCOPE STUDY [J].
HOHMAN, WR ;
SHAW, ST ;
MACAULAY, L ;
MOYER, DL .
CONTRACEPTION, 1977, 16 (05) :507-522
[8]   ENDOMETRIAL MORPHOLOGY WITH COPPER-BEARING INTRAUTERINE-DEVICES [J].
HSU, C ;
FERENCZY, A ;
RICHART, RM ;
DARABI, K .
CONTRACEPTION, 1976, 14 (03) :243-260
[9]   PLASMINOGEN ACTIVATORS IN ENDOMETRIUM OF WOMEN USING INTRAUTERINE CONTRACEPTIVE DEVICES [J].
KASONDE, JM ;
BONNAR, J .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1976, 83 (04) :315-319
[10]   INCREASED FIBRINOLYTIC-ACTIVITY IN ENDOMETRIUM OF PATIENTS USING COPPER-IUD [J].
LARSSON, B ;
LIEDHOLM, P ;
SJOBERG, NO ;
ASTEDT, B .
CONTRACEPTION, 1974, 9 (05) :531-537