MIDDLE CEREBRAL-ARTERY - DETERMINATION OF FLOW VELOCITIES WITH MR ANGIOGRAPHY

被引:28
作者
MATTLE, H
EDELMAN, RR
WENTZ, KU
REIS, MA
ATKINSON, DJ
ELLERT, T
机构
[1] BETH ISRAEL HOSP,DEPT RADIOL,330 BROOKLINE AVE,BOSTON,MA 02215
[2] HARVARD UNIV,SCH MED,BOSTON,MA 02115
[3] UNIV HEIDELBERG,KLINIKUM MANNHEIM,DEPT RADIOL,W-6800 MANNHEIM 1,GERMANY
[4] NEW ENGLAND DEACONESS HOSP,DEPT RADIOL,BOSTON,MA 02215
[5] SIEMENS MED SYST INC,ISELIN,NJ
关键词
BLOOD; FLOW DYNAMICS; CEREBRAL ANGIOGRAPHY; CEREBRAL BLOOD VESSELS; MR STUDIES; MAGNETIC RESONANCE (MR); EXPERIMENTAL;
D O I
10.1148/radiology.181.2.1924799
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A magnetic resonance (MR) angiographic technique for noninvasive measurement of flow velocities in the intracranial cerebral arteries was studied. Velocity measurements were made in a phantom and in the middle cerebral artery of six volunteers. Velocities were assessed in the volunteers before, during, and after finger movement. Average values for mean maximal velocities determined with MR angiography were 69.8 cm/sec before, 77.2 cm/sec during, and 69.6 cm/sec after finger movement. Correlations between values obtained with MR angiography and transcranial Doppler (TCD) sonography were r = .86 and P = .0001 for values obtained at rest and r = .84 and P = .0001 for values obtained during finger movement. The velocity increase during finger movement compared with that at rest was 11% for MR angiography and 11.3% for TCD sonography. Values measured with TCD sonography, however, were less than those measured with MR angiography (P = .001). The results show the feasibility of measuring flow velocities in intracranial arteries with MR angiography.
引用
收藏
页码:527 / 530
页数:4
相关论文
共 23 条
[1]   EVALUATION OF CEREBROVASCULAR SPASM WITH TRANSCRANIAL DOPPLER ULTRASOUND [J].
AASLID, R ;
HUBER, P ;
NORNES, H .
JOURNAL OF NEUROSURGERY, 1984, 60 (01) :37-41
[2]   CEREBRAL AUTO-REGULATION DYNAMICS IN HUMANS [J].
AASLID, R ;
LINDEGAARD, KF ;
SORTEBERG, W ;
NORNES, H .
STROKE, 1989, 20 (01) :45-52
[3]   NON-INVASIVE TRANSCRANIAL DOPPLER ULTRASOUND RECORDING OF FLOW VELOCITY IN BASAL CEREBRAL-ARTERIES [J].
AASLID, R ;
MARKWALDER, TM ;
NORNES, H .
JOURNAL OF NEUROSURGERY, 1982, 57 (06) :769-774
[4]  
AASLID R, 1986, TRANSCRANIAL DOPPLER
[5]  
AXEL L, 1986, Magnetic Resonance Imaging, V4, P199, DOI 10.1016/0730-725X(86)91059-3
[6]   PROJECTION ANGIOGRAMS OF BLOOD LABELED BY ADIABATIC FAST PASSAGE [J].
DIXON, WT ;
DU, LN ;
FAUL, DD ;
GADO, M ;
ROSSNICK, S .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (03) :454-462
[7]   MAGNETIC-RESONANCE ANGIOGRAPHY [J].
DUMOULIN, CL ;
HART, HR .
RADIOLOGY, 1986, 161 (03) :717-720
[8]   MAGNETIC-RESONANCE-IMAGING OF FLOW DYNAMICS IN THE CIRCLE OF WILLIS [J].
EDELMAN, RR ;
MATTLE, HP ;
OREILLY, GV ;
WENTZ, KU ;
LIU, C ;
ZHAO, B .
STROKE, 1990, 21 (01) :56-65
[9]   QUANTIFICATION OF BLOOD-FLOW WITH DYNAMIC MR IMAGING AND PRESATURATION BOLUS TRACKING [J].
EDELMAN, RR ;
MATTLE, HP ;
KLEEFIELD, J ;
SILVER, MS .
RADIOLOGY, 1989, 171 (02) :551-556
[10]   CEREBRAL BLOOD-FLOW - ASSESSMENT WITH DYNAMIC CONTRAST-ENHANCED T2-STAR-WEIGHTED MR IMAGING AT 1.5-T [J].
EDELMAN, RR ;
MATTLE, HP ;
ATKINSON, DJ ;
HILL, T ;
FINN, JP ;
MAYMAN, C ;
RONTHAL, M ;
HOOGEWOUD, HM ;
KLEEFIELD, J .
RADIOLOGY, 1990, 176 (01) :211-220