COMPARISON OF BACTEC PLUS 26 AND 27 MEDIA WITH AND WITHOUT FASTIDIOUS ORGANISM SUPPLEMENT WITH CONVENTIONAL METHODS FOR CULTURE OF STERILE BODY-FLUIDS

被引:26
作者
FULLER, DD
DAVIS, T
KIBSEY, PC
ROSMUS, L
AYERS, LW
OTT, M
SAUBOLLE, MA
SEWELL, DL
机构
[1] INDIANA UNIV,MED CTR,INDIANAPOLIS,IN
[2] GREY NUNS HOSP,EDMONTON,AB,CANADA
[3] OHIO STATE UNIV HOSP,COLUMBUS,OH 43210
[4] GOOD SAMARITAN REG MED CTR,PHOENIX,AZ
[5] VET AFFAIRS MED CTR,PORTLAND,OR
关键词
D O I
10.1128/JCM.32.6.1488-1491.1994
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
We compared the BACTEC Plus 26/27 culture system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) with and without fastidious organism supplement with conventional centrifugation preparation and plating for the recovery and speed of detection of microorganisms. A total of 1,101 sterile body fluid specimens were collected and processed at five hospital laboratories, yielding 234 (21%) positive cultures. Of the 176 isolates considered clinically significant, 133 (76%) were recovered by both the BACTEC system and conventional culture, while 28 (16% [P < 0.0051)]) were recovered by BACTEC only and 11 (6%) were recovered by conventional culture alone. There were no statistically significant differences in the speed of detection of microbial growth. It was found that BACTEC, with or without the addition of fastidious organism supplement, exhibited improved sensitivity for the recovery of microorganisms, including fastidious bacteria.
引用
收藏
页码:1488 / 1491
页数:4
相关论文
共 18 条
[1]  
BLONDEAU JM, 1993, 93 GEN M AM SOC MICR, P514
[2]  
DAVIS T, 1992, 92 GEN M AM SOC MICR, P428
[3]   CLINICAL AND MICROBIOLOGICAL EVALUATION OF 4 CULTURE METHODS FOR THE DIAGNOSIS OF PERITONITIS IN PATIENTS ON CONTINUOUS AMBULATORY PERITONEAL-DIALYSIS [J].
DOYLE, PW ;
CRICHTON, EP ;
MATHIAS, RG ;
WERB, R .
JOURNAL OF CLINICAL MICROBIOLOGY, 1989, 27 (06) :1206-1209
[4]  
ISENBERG HD, 1991, MANUAL CLIN MICROBIO, P15
[5]   TUBERCULOUS PLEURAL EFFUSIONS - INCREASED CULTURE YIELD WITH BEDSIDE INOCULATION OF PLEURAL FLUID AND POOR DIAGNOSTIC-VALUE OF ADENOSINE-DEAMINASE [J].
MAARTENS, G ;
BATEMAN, ED .
THORAX, 1991, 46 (02) :96-99
[6]   ADDI-CHEK FILTRATION, BACTEC, AND 10-ML CULTURE METHODS FOR RECOVERY OF MICROORGANISMS FROM DIALYSIS EFFLUENT DURING EPISODES OF PERITONITIS [J].
MALES, BM ;
WALSHE, JJ ;
GARRINGER, L ;
KOSCINSKI, D ;
AMSTERDAM, D .
JOURNAL OF CLINICAL MICROBIOLOGY, 1986, 23 (02) :350-353
[7]  
MANDELL GL, 1990, PRINCIPLES PRACTICE, P33
[8]  
MCNEMAR Q, 1962, PSYCHOL STAT, P209
[9]   EVALUATION OF BROTH MEDIA FOR ROUTINE CULTURE OF CEREBROSPINAL AND JOINT FLUID SPECIMENS [J].
REINHOLD, CE ;
NICKOLAI, DJ ;
PICCINNI, TE ;
BYFORD, BA ;
YORK, MK ;
BROOKS, GF .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1988, 89 (05) :671-674
[10]   BEDSIDE INOCULATION OF BLOOD CULTURE BOTTLES WITH ASCITIC FLUID IS SUPERIOR TO DELAYED INOCULATION IN THE DETECTION OF SPONTANEOUS BACTERIAL PERITONITIS [J].
RUNYON, BA ;
ANTILLON, MR ;
AKRIVIADIS, EA ;
MCHUTCHISON, JG .
JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (12) :2811-2812