Reference coordinates based on the finite helical axis for flexion of the knee from 0 to 90 deg are proposed. Six degree-of-freedom tracking allows the use of such a helical axis as a kinematic landmark for knee motion representation. Data from five human subjects in vivo are presented as a path of finite helical axes for flexion of the knee from 20 to 80 deg. The finite helical axis rotates by an average of 11.4 deg, the centrode translates an average of 19.8 mm, and the total axial translation averages 0.1 mm during flexion from 20 to 80 deg. Error due to the transducer was measured on a fixed-pivot pendulum and found to be 1.0 deg and 1.9 mm rms for the helical axis orientation and position, respectively, and 0.1 mm for the axial translation. Reproducibility and soft tissue effects on the measurements were repeatable to 4.0 deg and 2.7 mm rms in orientation and position, respectively, and 0.1 mm for the axial translations. Soft tissue errors averaged 4.9 deg and 3.6 mmm in position and orientation, and 0.3 mm in the axial translations.
引用
收藏
页码:215 / 222
页数:8
相关论文
共 25 条
[1]  
[Anonymous], 1969, DATA REDUCTION ERROR
[2]   3-DIMENSIONAL STUDY OF KINEMATICS OF HUMAN KNEE [J].
BLACHARSKI, PA ;
SOMERSET, JH ;
MURRAY, DG .
JOURNAL OF BIOMECHANICS, 1975, 8 (06) :375-+
[3]   THE ENVELOPE OF PASSIVE KNEE-JOINT MOTION [J].
BLANKEVOORT, L ;
HUISKES, R ;
DELANGE, A .
JOURNAL OF BIOMECHANICS, 1988, 21 (09) :705-+
[4]   ONE PARAMETER MODEL FOR ERROR IN INSTANTANEOUS CENTER OF ROTATION MEASUREMENTS [J].
BRYANT, JT ;
WEVERS, HW ;
LOWE, PJ .
JOURNAL OF BIOMECHANICS, 1984, 17 (05) :317-323
[5]   JUSTIFICATION OF TRIAXIAL GONIOMETER FOR THE MEASUREMENT OF JOINT ROTATION [J].
CHAO, EYS .
JOURNAL OF BIOMECHANICS, 1980, 13 (12) :989-+
[6]  
FIJAN RS, THESIS MIT
[7]   BIOMECHANICS OF INTERNAL DERANGEMENT OF KNEE - PATHOMECHANICS AS DETERMINED BY ANALYSIS OF INSTANT CENTERS OF MOTION [J].
FRANKEL, VH ;
BURSTEIN, AH ;
BROOKS, DB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1971, A 53 (05) :945-&
[8]   KINEMATICS OF HUMAN KNEE JOINT [J].
FREUDENS.F ;
WOO, LS .
BULLETIN OF MATHEMATICAL BIOPHYSICS, 1969, 31 (02) :215-&
[9]  
GOLDSTEIN H, 1965, CLASSICAL MECHANICS
[10]   A JOINT COORDINATE SYSTEM FOR THE CLINICAL DESCRIPTION OF 3-DIMENSIONAL MOTIONS - APPLICATION TO THE KNEE [J].
GROOD, ES ;
SUNTAY, WJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (02) :136-144