COMPARATIVE CRANIAL CT ENHANCEMENT IN THE NORMAL PRIMATE

被引:9
作者
DRAYER, BP
WOLFSON, SK
ROSENBAUM, AE
DUJOVNY, M
BOEHNKE, M
COOK, EE
机构
[1] UNIV PITTSBURGH,SCH MED,DEPT NEUROL,PITTSBURGH,PA 15261
[2] UNIV PITTSBURGH,SCH MED,DEPT NEUROSURG,PITTSBURGH,PA 15261
[3] MONTEFIORE HOSP,DEPT RADIOL,PITTSBURGH,PA 15213
[4] MONTEFIORE HOSP,DEPT LAB SURG RES,PITTSBURGH,PA 15213
关键词
Baboon; Cerebral blood flow; Computed tomography; Cranium; Metrizamide; Xenon;
D O I
10.1097/00004424-197901000-00014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The application of intravenous, intrathecal, and inhalation enhancement techniques to the CT evaluation of the nonhuman primate (Papio cynocephalus/aniibis) is described. The falx cerebri cortical vasculature, vein of Galen, straight sinus and tentorium cerebelli were defined with intravenous enhancement. Intrathecal CT enhancement with air was limited by distortion in cerebrospinal fluid spaces. Intrathecal CT enhancement using a low dose of metrizamide accurately delineated the subarachnoid spaces and the brain substance they surrounded with minimal morbidity. Symmetrical brain enhancement (perfusion) was prominent following inhalation CT enhancement; the degree of enhancement correlated with the estimated xenon concentration in the bloodstream. In addition, by performing repeated CT scans during the clearance of xenon from the brain, an approximate analysis of regional cerebral blood flow was obtained. © J. B. Lippincott Co.
引用
收藏
页码:88 / 96
页数:9
相关论文
共 20 条
[1]  
COLLINS V, 1976, PRINCIPLES ANESTHESI, P1541
[2]   THE ANESTHETIC PROPERTIES OF XENON IN ANIMALS AND HUMAN BEINGS, WITH ADDITIONAL OBSERVATIONS ON KRYPTON [J].
CULLEN, SC ;
GROSS, EG .
SCIENCE, 1951, 113 (2942) :580-582
[3]   POSTERIOR-FOSSA EXTRA-AXIAL CYST - DIAGNOSIS WITH METRIZAMIDE-CT CISTERNOGRAPHY [J].
DRAYER, BP ;
ROSENBAUM, AE ;
MAROON, JC ;
BANK, WO ;
WOODFORD, JE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1977, 128 (03) :431-436
[4]   COMPUTED TOMOGRAPHIC DIAGNOSIS OF SUPRASELLAR MASSES BY INTRATHECAL ENHANCEMENT [J].
DRAYER, BP ;
ROSENBAUM, AE ;
KENNERDELL, JS ;
ROBINSON, AG ;
BANK, WO ;
DEEB, ZL .
RADIOLOGY, 1977, 123 (02) :339-344
[5]   XENON ENHANCED CT FOR ANALYSIS OF CEREBRAL INTEGRITY, PERFUSION, AND BLOOD-FLOW [J].
DRAYER, BP ;
WOLFSON, SK ;
REINMUTH, OM ;
DUJOVNY, M ;
BOEHNKE, M ;
COOK, EE .
STROKE, 1978, 9 (02) :123-130
[6]   CEREBROSPINAL-FLUID IMAGING USING SERIAL METRIZAMIDE CT CISTERNOGRAPHY [J].
DRAYER, BP ;
ROSENBAUM, AE ;
HIGMAN, HB .
NEURORADIOLOGY, 1977, 13 (01) :7-17
[7]   EXTRAVASCULAR COMPONENT OF CONTRAST ENHANCEMENT IN CRANIAL COMPUTED TOMOGRAPHY .2. CONTRAST ENHANCEMENT AND BLOOD-TISSUE BARRIER [J].
GADO, MH ;
PHELPS, ME ;
COLEMAN, RE .
RADIOLOGY, 1975, 117 (03) :595-597
[8]   COMPUTER-ASSISTED TOMOGRAPHY OF INTRACRANIAL CSF CIRCULATION USING A WATER-SOLUBLE CONTRAST-MEDIUM [J].
GREITZ, T ;
HINDMARSH, T .
ACTA RADIOLOGICA-DIAGNOSIS, 1974, 15 (05) :497-507
[9]  
GREPE A, 1973, ACTA RADIOL S335, P119
[10]  
HOEDTRASMUSSEN K, 1966, CIRC RES, V18, P237