FACTORS AFFECTING THE ESTIMATION OF PHYSICAL WORKING CAPACITY AT THE FATIGUE THRESHOLD

被引:41
作者
DEVRIES, HA [1 ]
HOUSH, TJ [1 ]
JOHNSON, GO [1 ]
EVANS, SA [1 ]
THARP, GD [1 ]
HOUSH, DJ [1 ]
HUGHES, RA [1 ]
机构
[1] UNIV NEBRASKA, HUMAN PERFORMANCE LAB, COLISEUM 28, LINCOLN, NE 68588 USA
关键词
Electromyography; Fatigue threshold; Physical working capacity;
D O I
10.1080/00140139008927091
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The purpose of this study was to investigate potential improvements in the methodology associated with the Physical Working Capacity at the Fatigue Threshold (PWCFT) test including: (1) the use of a continuous test protocol; (2) the use of a treadmill; (3) the use of a bipolar EMG lead system for noisy electronic environments; and (4) the potential for residual fatigue from tests repeated 24 hours apart. The results of the continuous test protocol (X¯ ± S.D. = 210±73 watts) correlated well (r = 0·856) with the original discontinuous technique (222± 83 watts) and there was no significant (p> 0·05) difference between the mean values (t= 1·146). Treadmill testing required a bipolar lead system to counteract the electrical noise generated by the treadmill motor. The heart rate values which corresponded to PWCFT on the treadmill (W¯+s.d. = 164±b.p.m.) and bicycle ergometer (153 ± 18 b.p.m.) were highly correlated (r=0·833) and there was no significant (p>0·05) difference between the mean values (t= 2·22). The use of a bipolar lead EMG system on the bicycle ergometer resulted in significantly (p<0·05) smaller voltage for any given power output, and the PWCFT exhibited a low to moderate correlation (r=0·60) with PWCFM derived from a unipolar arrangement. The test-retest results of discontinuous PWCFM measurements performed 24 hours apart on the bicycle ergometer were correlated at r=0·812 with no significant (p>0·05) difference (=0·52) between the mean values (test=198±60; retest=191±63 watts).It was concluded that the continuous protocol using a bicycle ergometer should be considered an attractive alternative to the original discontinuous PWCFM test, and daily testing (using the discontinuous procedures) resulted in no residual fatigue. The use of a treadmill or bipolar lead system for the determination of PWCFM requires further study with respect to both validity and reproducibility. © 1990 Taylor & Francis Ltd.
引用
收藏
页码:25 / 33
页数:9
相关论文
共 8 条
[1]  
De Lisa J A, 1983, Electromyogr Clin Neurophysiol, V23, P651
[2]  
DEVRIES HA, 1976, AM J PHYS MED REHAB, V55, P139
[3]  
DEVRIES HA, 1968, AMER J PHYSICAL MED, V47, P10
[4]   ESTIMATING PHYSICAL WORKING CAPACITY AND TRAINING CHANGES IN THE ELDERLY AT THE FATIGUE THRESHOLD (PWCFT) [J].
DEVRIES, HA ;
BRODOWICZ, GR ;
ROBERTSON, LD ;
SVOBODA, MD ;
SCHENDEL, JS ;
TICHY, AM ;
TICHY, MW .
ERGONOMICS, 1989, 32 (08) :967-977
[5]   A METHOD FOR ESTIMATING PHYSICAL WORKING CAPACITY AT THE FATIGUE THRESHOLD (PWCFT) [J].
DEVRIES, HA ;
TICHY, MW ;
HOUSH, TJ ;
SMYTH, KD ;
TICHY, AM ;
HOUSH, DJ .
ERGONOMICS, 1987, 30 (08) :1195-1204
[6]  
Fischer A, 1961, HLTH FITNESS MODERN
[7]  
MORITANI T, 1978, AM J PHYS MED REHAB, V57, P263