CORONARY STENTING WITH A NEW, RADIOPAQUE, BALLOON-EXPANDABLE ENDOPROSTHESIS IN PIGS

被引:59
作者
VANDERGIESSEN, WJ
SERRUYS, PW
VANBEUSEKOM, HMM
VANWOERKENS, LJ
VANLOON, H
SOEI, LK
STRAUSS, BH
BEATT, KJ
VERDOUW, PD
机构
[1] ERASMUS UNIV,THORAXCTR,DEPT CARDIOL,POB 1738,3000 DR ROTTERDAM,NETHERLANDS
[2] ACAD HOSP ROTTERDAM DIJKZIGT,ROTTERDAM,NETHERLANDS
关键词
PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY; STENTS; PROSTHESES; ELECTRON MICROSCOPY;
D O I
10.1161/01.CIR.83.5.1788
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Intracoronary stents may be effective when used as "bail-out" devices for acute complications after percutaneous transluminal coronary angioplasty. Furthermore, preliminary reports have demonstrated some promising results with stents with regard to the reduction of restenosis. Several stent devices are available for preclinical and clinical evaluation. The use of these stainless-steel stents has been limited by poor visibility during fluoroscopy and thrombogenicity during the first days to weeks after implantation. We therefore investigated the immediate and short-term effects on arterial patency of a new, radiopaque, balloon-expandable coil stent in normal coronary arteries of pigs. Methods and Results. In 10 animals, a stent was placed in two of the three epicardial coronary arteries. During the implantation procedure, the animals received heparin; after the procedure, no antithrombotic drugs were administered. After 1 week (five animals and 10 stents) or 4 weeks (five animals and 10 stents), repeat angiography was performed, followed by pressure-fixation of the coronary arteries for light and electron microscopic examination. Angiographic analysis revealed that all stented coronary segments were patent and without signs of intraluminal defects. Scanning electron microscopy showed complete endothelial covering of all stents within 7 days. Light microscopy showed a reduced tunica media locally under the stent wires, which resulted from exerted pressure. The neointima on top of the stent wires measured 56-mu-m (range, 42-88-mu-m) after 1 week and 139-mu-m (range, 84-250-mu-m) after 4 weeks. Conclusions. Results from this study show that this radiopaque endoprosthesis can be safely placed in normal coronary arteries of pigs. After 4 weeks, all stents were patent and there was no need for additional antithrombotic treatment, whereas neointimal proliferation was limited.
引用
收藏
页码:1788 / 1798
页数:11
相关论文
共 44 条
  • [1] ANDERSON HV, 1985, AM J CARDIOL, V56, P712
  • [2] INTIMAL PROLIFERATION OF SMOOTH-MUSCLE CELLS AS AN EXPLANATION FOR RECURRENT CORONARY-ARTERY STENOSIS AFTER PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY
    AUSTIN, GE
    RATLIFF, NB
    HOLLMAN, J
    TABEI, S
    PHILLIPS, DF
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (02) : 369 - 375
  • [3] BAIM DS, 1989, CIRCULATION S2, V80, P174
  • [4] FLEXIBLE TANTALUM STENTS IMPLANTED IN AORTAS AND ILIAC ARTERIES - EFFECTS IN NORMAL CANINES
    BARTH, KH
    VIRMANI, R
    STRECKER, EP
    SAVIN, MA
    LINDISCH, D
    MATSUMOTO, AH
    TEITELBAUM, GP
    [J]. RADIOLOGY, 1990, 175 (01) : 91 - 96
  • [5] BEATT K J, 1989, Journal of the American College of Cardiology, V13, p224A
  • [6] MEDICAL APPROACHES TO PREVENTION OF RESTENOSIS AFTER CORONARY ANGIOPLASTY
    BLACKSHEAR, JL
    OCALLAGHAN, WG
    CALIFF, RM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (04) : 834 - 848
  • [7] IN-HOSPITAL MORBIDITY AND MORTALITY IN PATIENTS UNDERGOING ELECTIVE CORONARY ANGIOPLASTY
    BREDLAU, CE
    ROUBIN, GS
    LEIMGRUBER, PP
    DOUGLAS, JS
    KING, SB
    GRUENTZIG, AR
    [J]. CIRCULATION, 1985, 72 (05) : 1044 - 1052
  • [8] Chesebro JH, 1989, CIRCULATION S2, V80, pII
  • [9] REDUCTION IN THE RATE OF EARLY RESTENOSIS AFTER CORONARY ANGIOPLASTY BY A DIET SUPPLEMENTED WITH N-3 FATTY-ACIDS
    DEHMER, GJ
    POPMA, JJ
    VANDENBERG, EK
    EICHHORN, EJ
    PREWITT, JB
    CAMPBELL, WB
    JENNINGS, L
    WILLERSON, JT
    SCHMITZ, JM
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1988, 319 (12) : 733 - 740
  • [10] PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY IN 1985-1986 AND 1977-1981 - THE NATIONAL-HEART-LUNG-AND-BLOOD-INSTITUTE REGISTRY
    DETRE, K
    HOLUBKOV, R
    KELSEY, S
    COWLEY, M
    KENT, K
    WILLIAMS, D
    MYLER, R
    FAXON, D
    HOLMES, D
    BOURASSA, M
    BLOCK, P
    GOSSELIN, A
    BENTIVOGLIO, L
    LEATHERMAN, L
    DORROS, G
    KING, S
    GALICHIA, J
    ALBASSAM, M
    LEON, M
    ROBERTSON, T
    PASSAMANI, E
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1988, 318 (05) : 265 - 270