POWERFUL HE-3-HE-4 DILUTION REFRIGERATOR FOR FROZEN SPIN TARGET

被引:3
作者
BORISOV, NS
KULIKOV, VV
NEGANOV, AB
USOV, YA
机构
[1] Joint Institute for Nuclear Research, Laboratory of Nuclear Problems, Moscow
关键词
HE-3; HE-4; REFRIGERATORS; DILUTION REFRIGERATORS; FROZEN POLARIZED TARGET;
D O I
10.1016/0011-2275(93)90029-N
中图分类号
O414.1 [热力学];
学科分类号
摘要
The design and construction of a powerful He-3/He-4 dilution refrigerator are described, for which the lowest temperature in continuous operation was 20 mK and the typical cooling power was almost-equal-to 100 mW at 0.3 K. The refrigeration is primarily intended for cooling a large frozen polarized target.
引用
收藏
页码:738 / 741
页数:4
相关论文
共 13 条
[1]  
BALL J, 1984, 1984 P INT WORKSH PO, P112
[2]   FROZEN SPIN POLARIZED DEUTERON TARGET 60 CM3 IN VOLUME [J].
BORISOV, NS ;
BUNYATOVA, EI ;
LIBURG, MY ;
MATAFONOV, VN ;
NEGANOV, AB ;
USOV, YA .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1988, 21 (12) :1179-1182
[3]  
BORISOV NS, 1985, JINR 3185292 DUBN
[4]  
BORISOV NS, 1986, JINR P1384737 PREPR
[5]  
BORISOV NS, 1984, SOV PHYS JETP, V87, P2234
[6]  
BURKHIN MM, 1979, IHEP7994 PREPR SERP
[7]   DYNAMIC PROTON POLARIZATION IN PROPANEDIOL BELOW 0.5 K [J].
DEBOER, W ;
NIINIKOSKI, TO .
NUCLEAR INSTRUMENTS & METHODS, 1974, 114 (03) :495-498
[8]  
HALL HE, 1966, CRYOGENCIS, V6, P8
[9]  
Lounasmaa OV., 1974, EXPT PRINCIPLES METH
[10]  
NEGANOV AB, 1985, JINR885291 PREPR DUB