SUBCUTANEOUS BLOOD-FLOW OVER 24-HOUR PERIODS IN PATIENTS WITH SEVERE LEG ISCHEMIA

被引:3
作者
BJERREJEPSEN, K [1 ]
FARIS, I [1 ]
HENRIKSEN, O [1 ]
LASSEN, NA [1 ]
机构
[1] BISPEBJERG HOSP, DEPT CLIN PHYSIOL, DK-2400 COPENHAGEN NV, DENMARK
来源
CLINICAL PHYSIOLOGY | 1982年 / 2卷 / 05期
关键词
D O I
10.1111/j.1475-097X.1982.tb00041.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
A method for studying the clearance of 133Xe from the s.c. tissue of the calf and foot over 24-h periods was described. The average blood flow over this period can be estimated from the clearance constant obtained. Two series of measurement of the radioactivity are made, the first 2 h after the injection of 1-2 mCi 133Xe in saline and the 2nd, 18-24 h later. The distance between the detector and the depot is reproduced using a cylinder 20-cm-long. The median washout rate of the isotope (k) in 25 patients was 2.57 .times. 10-3 min-1 for the calf and 2.39 .times. 10-3 min-1 for the foot. The median difference between repeated measurements in the same patient was 0.24 .times. 10-3 min-1 in the calf and 0.43 .times. 10-3 min-1 in the foot. This method, which can be used to estimate the average blood flow over 24 h while the patient undertakes his normal activities, should be useful in assessing the effect of therapy on the blood flow to the limb.
引用
收藏
页码:357 / 362
页数:6