RADIOISOTOPIC PACEMAKER - LONG-TERM CLINICAL-RESULTS

被引:7
作者
CHAUVEL, C
LAVERGNE, T
COHEN, A
DUCIMETIERE, P
LEHEUZEY, JY
VALTY, J
GUIZE, L
机构
[1] ST ANTOINE UNIV HOSP,DEPT CARDIOL,PARIS,FRANCE
[2] BROUSSAIS UNIV HOSP,DEPT CARDIOL,PARIS,FRANCE
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1995年 / 18卷 / 02期
关键词
CARDIAC PACING; RADIOISOTOPE;
D O I
10.1111/j.1540-8159.1995.tb02518.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In order to prolong the service life of the generator, the isotopic pacemakers, powered by Pu-238, have been developed and implanted since 1970. We report the follow-up of 325 patients (mean age 39 +/- 18 years) implanted with an isotopic pulse generator (Medtronic 9000/9090) between April 1970 and July 1982. The mean follow-up was 12 years (range 6 days to 18.5 years). The generator was highly reliable; the mean value of pacing rate between implantation and last follow-up decreased significantly but no more than 1 beat/min (72.7 vs 71.8 beats/min; P < 0.001) and the pulse width did not change significantly. The actuarial survival of the device was 97% at 18.5 years. During the follow-up period, 122 reoperations were performed in 85 patients: 88 explantations of the entire pacing system and 34 modifications of the lead system. Lead dysfunction accounted for 68% of the 2 22 reoperations, generator failure for 6%, and miscellaneous reasons for 26%. However, 72% of patients remain free of intervention during the follow-up period and 61 patients (20%) died during this period. Most deaths (52%) were of nonsudden cardiovascular origin, 17% were related to cancer, and 13% to sudden death. After 5, 10, and 18.5 years, 94%, 89%, and 73% of the patients were alive, respectively. No side effect could be attributed to the radioisotope. We conclude that this isotopic pacemaker demonstrated its reliability for long-term cardiac pacing.
引用
收藏
页码:286 / 292
页数:7
相关论文
共 17 条
[1]  
ALAIS M, 1970, ANS T, V13, P508
[2]   PERFORMANCE OF IMPLANTABLE CARDIAC-RHYTHM MANAGEMENT DEVICES [J].
BILITCH, M ;
DENES, P ;
GOLDMAN, BS ;
MALONEY, JD ;
HARTHORNE, JW ;
GRIFFIN, JC ;
FURMAN, S ;
PARSONNET, V .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (03) :371-380
[3]   VENTRICULAR ARRHYTHMIAS IN POSTOPERATIVE TETRALOGY OF FALLOT [J].
CHANDAR, JS ;
WOLFF, GS ;
GARSON, A ;
BELL, TJ ;
BEDER, SD ;
BINKBOELKENS, M ;
BYRUM, CJ ;
CAMPBELL, RM ;
DEAL, BJ ;
DICK, M ;
FLINN, CJ ;
GAUM, WE ;
GILLETTE, PC ;
HORDOF, AJ ;
KUGLER, JD ;
PORTER, CBJ ;
WALSH, EP .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 65 (09) :655-661
[4]  
EDMONDS CM, 1973, 26TH P ANN C ENG MED, P358
[5]   STATUS OF THE ADULT AND ADOLESCENT AFTER REPAIR OF TETRALOGY OF FALLOT [J].
GARSON, A ;
NIHILL, MR ;
MCNAMARA, DG ;
COOLEY, DA .
CIRCULATION, 1979, 59 (06) :1232-1240
[6]  
HIXSON JD, 1972, 1972 P INT SOC EN C
[7]  
HUFFMAN FN, 1971, T AM NUCL SOC, V14, P510
[8]   3-YEARS CLINICAL EXPERIENCE WITH RADIOISOTOPE POWERED CARDIAC-PACEMAKERS [J].
KAHN, AR ;
HIXSON, JD ;
PUFFER, JE ;
BAKKEN, EE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1973, BM20 (05) :326-331
[9]  
LAURENS P, 1979, PACE, V3, P356
[10]  
LAURENS P, 1970, ARCH MAL COEUR, V63, P906