PERFORMANCE OF A URANIUM TETRAMETHYLPENTANE CALORIMETER BACKED BY AN IRON SCINTILLATOR CALORIMETER

被引:10
作者
APSIMON, R
机构
[1] Imperial College, London
[2] Queen Mary and Westfield College, London
[3] Rutherford Appleton Lab, Rutherford
关键词
D O I
10.1016/0168-9002(91)90549-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present results from the barrel depleted uranium/TMP calorimeter modules constructed by the UA1 Collaboration. Electromagnetic and hadronic energy resolutions have been measured using electron and pion beams with momenta in the range 7 to 70 GeV/c. Results on the energy linearity and the spatial uniformity of response are reported. The electromagnetic shower position resolution has been measured as a function of energy using a fine grained position detector placed at a depth of approximately 3.5 X0. The noise arising both from the electronics chain and from the uranium radioactivity is compared with 70 GeV/c muon signals. The ratio of the electron to pion response has been measured both as a function of the energy and of the electric field. The high lateral and longitudinal granularity of the calorimeter and the presence of a position detector have been used to determine the electron-pion separation as a function of energy.
引用
收藏
页码:331 / 343
页数:13
相关论文
共 7 条
  • [1] PERFORMANCE OF A URANIUM TETRAMETHYLPENTANE ELECTROMAGNETIC CALORIMETER
    ALBROW, MG
    APSIMON, R
    AUBERT, B
    BACCI, C
    BEZAGUET, A
    BONINO, R
    CENNINI, P
    CENTRO, S
    CERADINI, F
    COCHET, C
    COLAS, J
    CONTE, R
    DEBRION, JP
    DEGIORGI, M
    DICIACCIO, A
    DIEZHEDO, F
    DOWELL, JD
    DUMPS, L
    GHEZ, P
    GIVERNAUD, A
    GONIDEC, A
    KIENZLE, W
    LACAVA, F
    LOOTEN, A
    MARKIEWICZ, T
    MARKOU, C
    MAURIN, G
    MENEGUZZO, A
    MULLER, T
    MUNOZ, R
    NAUMANN, L
    OCHSENBEIN, S
    PETROLO, E
    PIGOT, C
    PLACCI, A
    PRIPSTEIN, M
    RADERMACHER, E
    ROBINSON, D
    RUBBIA, C
    SASS, J
    SCHINZEL, D
    SCHMIDT, WF
    SEEZ, C
    SEIDL, W
    STREETS, J
    SUMOROK, K
    VENEZIANO, S
    VIRDEE, TS
    WARMUTH, E
    ZANELLO, L
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 265 (1-2) : 303 - 318
  • [2] CONSTRUCTION AND PERFORMANCE OF A POSITION DETECTOR FOR THE UA1 URANIUM-TMP CALORIMETER
    ANKOVIAK, K
    BAUER, G
    BUCHANAN, C
    CLINE, D
    DICIACCIO, A
    EVANS, H
    FUESS, TA
    GEER, S
    GONIDEC, A
    GRONBERG, J
    LINDGREN, M
    MOHAMMADI, M
    MUNOZ, R
    NAUMANN, L
    RADERMACHER, E
    REVOL, JP
    ROHLF, J
    RUBBIA, C
    SADOWSKI, E
    SCHINZEL, D
    SEEZ, C
    SEIDL, W
    STORK, D
    SUMOROK, K
    TETHER, S
    WU, X
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 279 (1-2) : 83 - 90
  • [3] INFLUENCE OF THE ELECTRIC-FIELD ON COMPENSATION IN A URANIUM TETRAMETHYLPENTANE HADRONIC CALORIMETER
    BACCI, C
    BEZAGUET, A
    BLOESS, D
    CANER, A
    CAVANNA, F
    DIEZHEDO, FJ
    DRIJARD, D
    DUMPS, L
    DICIACCIO, A
    EVANS, H
    FERRANDO, A
    GIVERNAUD, A
    GONIDEC, A
    JOSA, MI
    KRAMMER, M
    LACAVA, F
    LINDGREN, M
    MARKOU, C
    MAURIN, G
    MORGAN, K
    MUNOZ, RC
    NAUMANN, L
    PETROLO, E
    PLACCI, A
    PONTECORVO, L
    RADERMACHER, E
    ROBINSON, D
    RODRIGO, T
    RUBBIA, C
    SALICIO, JM
    SCHINZEL, D
    SEEZ, C
    STUBENRAUCH, C
    TORRENTELUJAN, E
    TUSI, A
    ULLALAND, O
    VENEZIANO, S
    VIRDEE, TS
    VUILLEMIN, V
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 292 (01) : 113 - 120
  • [4] BACCI C, 1989, NUCL INSTRUM METH A, V279, P169
  • [5] A HYBRID CHARGE SENSITIVE AMPLIFIER FOR HIGH CAPACITANCE DETECTORS
    BACCI, C
    CENTRO, S
    DEGIORGI, M
    MARTINELLI, R
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (01) : 321 - 325
  • [6] PERFORMANCE OF A SEMI-OCTAGONAL-SHAPED URANIUM TETRAMETHYLPENTANE CALORIMETER
    BACCI, C
    BEZAGUET, A
    BLOESS, D
    CANER, A
    CAVANNA, F
    DIEZHEDO, FJ
    DRIJARD, D
    DUMPS, L
    EVANS, H
    FERRANDO, A
    GIVERNAUD, A
    GONIDEC, A
    JOSA, MI
    KRAMMER, M
    MARQUINA, MA
    MAURIN, G
    MORGAN, K
    MUNOZ, RC
    NAUMANN, L
    NEDELEC, P
    PETROLO, E
    PLACCI, A
    PONTECORVO, L
    RADERMACHER, E
    ROBINSON, D
    RODRIGO, T
    RUBBIA, C
    SALICIO, JM
    SCHINZEL, D
    SEEZ, C
    STUBENRAUCH, C
    TEYKAL, H
    TORRENTELUJAN, E
    TUSI, A
    ULLALAND, O
    VENEZIANO, S
    VIRDEE, TS
    VUILLEMIN, V
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 301 (03) : 445 - 450
  • [7] ELECTRON-DRIFT VELOCITIES AND ELECTRON MOBILITIES IN FAST ROOM-TEMPERATURE DIELECTRIC LIQUIDS AND THEIR CORRESPONDING VAPORS
    FAIDAS, H
    CHRISTOPHOROU, LG
    MCCORKLE, DL
    CARTER, JG
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 294 (03) : 575 - 582