VELOCITY AND FLOW QUANTITATION IN THE SUPERIOR SAGITTAL SINUS WITH UNGATED AND CINE (GATED) PHASE-CONTRAST MR-IMAGING

被引:24
作者
JORDAN, JE [1 ]
PELC, NJ [1 ]
ENZMANN, DR [1 ]
机构
[1] STANFORD UNIV,MED CTR,SCH MED,DEPT RADIOL,STANFORD,CA 94305
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1994年 / 4卷 / 01期
关键词
CEREBRAL BLOOD VESSELS; FLOW DYNAMICS; MR; PHASE IMAGING; VASCULAR STUDIES; VELOCITY STUDIES; VEINS;
D O I
10.1002/jmri.1880040108
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Normal blood flow and velocity in the superior sagittal sinus were measured in 30 patients. A fast two-dimensional ungated phase-contrast (PC) pulse sequence was compared with a peripherally gated cine PC technique for velocity and flow quantitation. The same imaging parameters were used for both methods. Measured values for mean velocity and flow obtained with the two methods were compared by using regression analysis and t testing. For blood flow, the correlation coefficient was.976. For velocity measurements, r was .950. Mean flow was 285 mL/min +/- 19 with the ungated PC method and 281 mL/min +/- 19 with the cine PC method. The mean velocities measured with the two methods were 12.94 cm/sec +/- 1.1 and 13.59 cm/sec +/- 1.1, respectively. There was no significant difference (paired t test) between the methods for mean flow or velocity data. This was true even though flow in the superior sagittal sinus is moderately pulsatile, as shown with the cine PC technique. The ungated PC method provided these data in 13 seconds versus 3.5 minutes for the cine PC method.
引用
收藏
页码:25 / 28
页数:4
相关论文
共 13 条
[1]   3-DIMENSIONAL PHASE-CONTRAST ANGIOGRAPHY [J].
DUMOULIN, CL ;
SOUZA, SP ;
WALKER, MF ;
WAGLE, W .
MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (01) :139-149
[2]   NORMAL FLOW PATTERNS OF INTRACRANIAL AND SPINAL CEREBROSPINAL-FLUID DEFINED WITH PHASE-CONTRAST CINE MR IMAGING [J].
ENZMANN, DR ;
PELC, NJ .
RADIOLOGY, 1991, 178 (02) :467-474
[3]  
HOFMAN MBM, 1991, BOOK ABSTRACTS SOC M, P808
[4]  
HOFMAN MBM, 1992, BOOK ABSTRACTS SOC M, P1106
[5]   DETERMINATION OF CEREBRAL BLOOD-FLOW WITH A PHASE-CONTRAST CINE MR IMAGING TECHNIQUE - EVALUATION OF NORMAL SUBJECTS AND PATIENTS WITH ARTERIOVENOUS-MALFORMATIONS [J].
MARKS, MP ;
PELC, NJ ;
ROSS, MR ;
ENZMANN, DR .
RADIOLOGY, 1992, 182 (02) :467-476
[6]   FLOW QUANTIFICATION IN THE SUPERIOR SAGITTAL SINUS USING MAGNETIC-RESONANCE [J].
MATTLE, H ;
EDELMAN, RR ;
REIS, MA ;
ATKINSON, DJ .
NEUROLOGY, 1990, 40 (05) :813-815
[7]  
PELC N J, 1991, Magnetic Resonance Quarterly, V7, P229
[8]  
RIPPE DJ, 1990, AM J NEURORADIOL, V11, P199
[9]  
RUBIN DL, 1990, BOOK ABSTRACTS SOC M, P90
[10]   RAPID MR IMAGING OF BLOOD-FLOW WITH A PHASE-SENSITIVE, LIMITED-FLIP-ANGLE, GRADIENT RECALLED PULSE SEQUENCE - PRELIMINARY EXPERIENCE [J].
SPRITZER, CE ;
PELC, NJ ;
LEE, JN ;
EVANS, AJ ;
SOSTMAN, HD ;
RIEDERER, SJ .
RADIOLOGY, 1990, 176 (01) :255-262