DEVELOPMENT AND CHARACTERIZATION OF AN AUTOMATED FLOW SYSTEM FOR VOLTAMMETRIC ANALYSIS

被引:9
作者
MAHONEY, LA [1 ]
ODEA, J [1 ]
OSTERYOUNG, JG [1 ]
机构
[1] N CAROLINA STATE UNIV,DEPT CHEM,RALEIGH,NC 27695
关键词
ANODIC STRIPPING VOLTAMMETRY; COULOMETRY; FLOW INJECTION; FLOW SYSTEM; VOLTAMMETRY; AUTOMATION;
D O I
10.1016/0003-2670(93)85336-I
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow system for voltammetric analysis is described and characterized. This system was designed so that sample manipulation and electrochemical experiments could be performed under automated control. The goal of this work is to expand the practical possibilities for elucidation of the electrochemical behavior of chemical systems. An auxiliary goal is to exploit the potential of flow systems combined with pulse voltammetry for chemical analysis. Once a system has been characterized systematically to establish optimal conditions, voltammograms may be subjected to kinetic analysis. The test system employed here is the reduction and anodic stripping of Pb(II). The accuracy of the sample delivery system was tested by producing calibration curves, which were linear over the range of 0-100% mixing, with correlation coefficients greater than 0.999. The introduction of the sample by means of a sample injector was evaluated along with the effect of the carrier flow-rate on anodic stripping voltammograms. The optimum conditions of 1 ml min-1 carrier flow-rate and 150% carrier sweep volume of the loop were determined. Although the flow cell detector is of the wall jet style, the effect of flow-rate on anodic stripping currents is not that of wall jet behavior. The reproducibility of the flow system, for optimum conditions, matched that of the detector for static cell experiments. Finally, the conversion efficiency of the detector was determined to be approximately 1%.
引用
收藏
页码:25 / 33
页数:9
相关论文
共 22 条
[1]  
APPELQVIST R, 1986, ANAL CHIM ACTA, V180, P1
[2]  
BRODKEY RS, 1988, TRANSPORT PHENOMENA, P599
[3]   FLOW-INJECTION CYCLIC VOLTAMMETRY [J].
CANETE, F ;
RIOS, A ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICA CHIMICA ACTA, 1988, 211 (1-2) :287-292
[4]   THEORETICAL AND PRACTICAL LIMITATIONS ON THE OPTIMIZATION OF AMPEROMETRIC DETECTORS [J].
ELBICKI, JM ;
MORGAN, DM ;
WEBER, SG .
ANALYTICAL CHEMISTRY, 1984, 56 (06) :978-985
[5]   DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY AT THE WALL JET ELECTRODE [J].
GUNASINGHAM, H ;
ANG, KP ;
NGO, CC ;
THIAK, PC .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 198 (01) :27-35
[6]   THEORETICAL COMPARISON OF THE PERFORMANCE OF ELECTROCHEMICAL FLOW-THROUGH DETECTORS [J].
HANEKAMP, HB ;
DEJONG, HG .
ANALYTICA CHIMICA ACTA, 1982, 135 (02) :351-354
[7]   ELECTROANALYTICAL VOLTAMMETRY IN FLOWING SOLUTIONS [J].
JOHNSON, DC ;
WEBER, SG ;
BOND, AM ;
WIGHTMAN, RM ;
SHOUP, RE ;
KRULL, IS .
ANALYTICA CHIMICA ACTA, 1986, 180 :187-250
[8]  
OSTERYOUNG J, 1986, ELECTROANAL CHEM, V14, P209
[9]   FLOW-INJECTION ANALYSIS AND CHROMATOGRAPHY - TWINS OR SIBLINGS - PLENARY LECTURE [J].
RUZICKA, J ;
CHRISTIAN, GD .
ANALYST, 1990, 115 (05) :475-486
[10]  
RUZICKA J, 1983, ANAL CHEM, V55, P1040