DETERMINATION OF REDUCED SCATTERING AND ABSORPTION-COEFFICIENTS BY A SINGLE CHARGE-COUPLED-DEVICE ARRAY MEASUREMENT .2. MEASUREMENTS ON BIOLOGICAL TISSUES

被引:18
作者
BEVILACQUA, F [1 ]
MARQUET, P [1 ]
DEPEURSINGE, C [1 ]
DEHALLER, EB [1 ]
机构
[1] UNIV MUNSTER, INST EXPTL AUDIOL, BIOPHYS LAB, D-48129 MUNSTER, GERMANY
关键词
TISSUE OPTICS; MONTE CARLO; ABSORPTION COEFFICIENT; SCATTERING COEFFICIENT;
D O I
10.1117/12.204799
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The optical properties of various biological tissues have been investigated by the measurement of the maximum intensity M and the full width at half maximum (FWHM) of the intensity profile of a scattered light beam. These two quantities have turned out to be highly discriminating parameters for the different tissues under scrutiny: muscle, liver, adipose, and gray and white brain matter, The inverse problem, i.e., the computation of the absorption and reduced scattering coefficients from M and FWHM, has been solved in the domains where Monte Carlo simulations have yielded possible values for M and FWHM. The accuracy is typically 5% for the reduced scattering coefficient and 20% for the absorption coefficient. This method is judged to be reasonably good for application to biological materials it allows a good overall characterization of tissues. A scanning technique has been developed to evaluate the variability of the optical parameters at different locations in biological tissues, Whereas Monte Carlo simulation works well for tissues such as muscle or liver, it appears to be inappropriate in describing the optical properties of adipose and brain tissues. The reasons are still unclear and are probably related to the particular structural properties of such tissues.
引用
收藏
页码:2064 / 2069
页数:6
相关论文
共 14 条
[1]  
BEAUVOIT B, 1994, P SOC PHOTO-OPT INS, V2326, P127
[2]   A REVIEW OF THE OPTICAL-PROPERTIES OF BIOLOGICAL TISSUES [J].
CHEONG, WF ;
PRAHL, SA ;
WELCH, AJ .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1990, 26 (12) :2166-2185
[3]   SCATTERING AND ABSORPTION OF TURBID MATERIALS DETERMINED FROM REFLECTION MEASUREMENTS .2. MEASURING METHOD AND CALIBRATION [J].
GROENHUIS, RAJ ;
TENBOSCH, JJ ;
FERWERDA, HA .
APPLIED OPTICS, 1983, 22 (16) :2463-2467
[4]  
HEBEDA KM, 1994, P SOC PHOTO-OPT INS, V2077, P213, DOI 10.1117/12.168031
[5]  
Jacques S. L., 1987, Lasers in the Life Sciences, V1, P309
[6]   APPLICATIONS OF THE 1-D DIFFUSION-APPROXIMATION TO THE OPTICS OF TISSUES AND TISSUE PHANTOMS [J].
KARAGIANNES, JL ;
ZHANG, Z ;
GROSSWEINER, B ;
GROSSWEINER, LI .
APPLIED OPTICS, 1989, 28 (12) :2311-2317
[7]  
MARIJNISSEN J P A, 1987, Lasers in Medical Science, V2, P235, DOI 10.1007/BF02594166
[8]  
MARIJNISSEN JPA, 1985, PHOTODYNAMIC THERAPY
[9]   DETERMINATION OF REDUCED SCATTERING AND ABSORPTION-COEFFICIENTS BY A SINGLE CHARGE-COUPLED-DEVICE ARRAY MEASUREMENT .1. COMPARISON BETWEEN EXPERIMENTS AND SIMULATIONS [J].
MARQUET, P ;
BEVILACQUA, F ;
DEPEURSINGE, C ;
DEHALLER, EB .
OPTICAL ENGINEERING, 1995, 34 (07) :2055-2063
[10]  
SANDEMAN DR, 1986, LASER MED SCI, V3, P47