INADEQUACY OF STEADY-STATE ANALYSIS FOR FEEDBACK-CONTROL - DISTILLATE-BOTTOM CONTROL OF DISTILLATION-COLUMNS

被引:30
作者
SKOGESTAD, S [1 ]
JACOBSEN, EW [1 ]
MORARI, M [1 ]
机构
[1] CALTECH,CHEM ENGN 21041,PASADENA,CA 91125
关键词
D O I
10.1021/ie00108a006
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
It is often claimed that for distillation columns the steady-state description is much more important than the dynamic description for control purposes. The ultimate counterexample to this misconseption is the recently proposed distillate-bottom (DB) configuration that involves using distillate and bottom flow to control compositions. This control scheme has previously been labeled “impossible” by most distillation control experts because D and B are not independent at steady state (since D + B = F) and the gain matrix is singular. Yet, as shown by Finco et al. for a propane-propylene splitter, both with simulations and with implementation, the scheme does actually work. Finco et al. do not provide any explanations for this, but as shown in this paper, the main reason is the flow dynamics (liquid lag from the top to the bottom of the column), which decouples the responses at high frequency (initial response) and makes the system quite easy to control. The results in this paper demonstrate that steady-state data may be entirely misleading for evaluating control performance. This is of course well-known, for example, from the Ziegler-Nichols tuning rules, which are based on high-frequency behavior only, but often seems to be forgotten when analyzing multivariable systems. © 1990, American Chemical Society. All rights reserved.
引用
收藏
页码:2339 / 2346
页数:8
相关论文
共 16 条
[1]  
FINCO MV, 1989, IND ENG CHEM RES, V28, P76
[2]   CLOSED-LOOP PROPERTIES FROM STEADY-STATE GAIN INFORMATION [J].
GROSDIDIER, P ;
MORARI, M ;
HOLT, BR .
INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1985, 24 (02) :221-235
[3]   TRANSFORMATIONS AND CONSISTENCY RELATIONS OF DISTILLATION CONTROL-STRUCTURES [J].
HAGGBLOM, KE ;
WALLER, KV .
AICHE JOURNAL, 1988, 34 (10) :1634-1648
[4]  
MCCUNE LC, 1973, ISA T, V12, P193
[5]  
NETT CN, 1987, JUN AM CONTR C MINN
[6]  
PERRY H, 1973, CHEM ENG HDB
[7]  
SHINSKEY F. G., 1984, DISTILLATION CONTROL
[8]   LV-CONTROL OF A HIGH-PURITY DISTILLATION COLUMN [J].
SKOGESTAD, S ;
MORARI, M .
CHEMICAL ENGINEERING SCIENCE, 1988, 43 (01) :33-48
[9]   CONTROL CONFIGURATION SELECTION FOR DISTILLATION-COLUMNS [J].
SKOGESTAD, S ;
MORARI, M .
AICHE JOURNAL, 1987, 33 (10) :1620-1635
[10]   SELECTING THE BEST DISTILLATION CONTROL CONFIGURATION [J].
SKOGESTAD, S ;
LUNDSTROM, P ;
JACOBSEN, EW .
AICHE JOURNAL, 1990, 36 (05) :753-764