THE LASER SYSTEM FOR CALIBRATION AND MONITORING OF THE OPAL JET CHAMBER

被引:5
作者
BIEBEL, O
BODEN, B
BORNER, H
BREUKER, H
BUG, S
EYRING, A
FISCHER, HM
GEICHGIMBEL, C
GROSS, S
HAGEMANN, J
HAUSCHILD, M
HEUER, RD
KARNER, K
KNOP, G
LEVEGRUN, S
LINSER, G
MARINGER, G
MAUER, E
MAUR, U
NELLEN, B
NEUMANN, H
ROLLNIK, A
RUNOLFSSON, O
VONDERSCHMITT, H
SCHREIBER, S
SEIDL, W
SIMON, A
THIEBES, J
VOILLAT, D
WAGNER, A
WICHT, P
WOLF, B
WUNSCH, B
机构
[1] UNIV HEIDELBERG,INST PHYS,W-6900 HEIDELBERG,GERMANY
[2] CERN,CH-1211 GENEVA 23,SWITZERLAND
关键词
D O I
10.1016/0168-9002(92)90777-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this report we describe the construction and performance of the laser system which was used in Summer 1989 for the initial calibration of the OPAL jet chamber after installation on the LEP beam axis and which has served as a monitoring tool since then Two Nd:YAG lasers are used to generate 48 high precision double beams which enter the chamber at fixed positions. The main features of the roughly 450 optical components are described and the beam alignment procedures are explained. Results are given for jet chamber calibration constants such as drift velocity, Lorentz angle. and residual sagittas.
引用
收藏
页码:183 / 200
页数:18
相关论文
共 20 条
[1]  
AHMET K, 1991, NUCL INSTRUM METH A, V305, P275
[2]   NEW METHOD FOR TESTING AND CALIBRATING IONIZING PARTICLE DETECTORS [J].
ANDERHUB, H ;
DEVEREUX, MJ ;
SEILER, PG .
NUCLEAR INSTRUMENTS & METHODS, 1979, 166 (03) :581-582
[3]   ON A NEW METHOD FOR TESTING AND CALIBRATING WIRE CHAMBERS [J].
ANDERHUB, H ;
DEVEREUX, M ;
SEILER, PG .
NUCLEAR INSTRUMENTS & METHODS, 1980, 176 (1-2) :323-324
[4]   IONIZATION OF MULTIWIRE PROPORTIONAL CHAMBER GAS BY DOUBLE PHOTON-ABSORPTION [J].
BOUROTTE, J ;
SADOULET, B .
NUCLEAR INSTRUMENTS & METHODS, 1980, 173 (03) :463-470
[5]  
CAHILL JW, 1986, J PHYS B ATOM MOL PH, V19, P1989
[6]   MEASUREMENT OF LASER-INDUCED IONIZATION IN AN ARGON ETHANE GAS-MIXTURE [J].
DESALVO, M ;
DESALVO, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 201 (2-3) :357-360
[7]  
EYRING A, 1990, INTERNAL REPORT BONN
[8]   THE OPAL JET CHAMBER [J].
FISCHER, HM ;
HARTMANN, H ;
HAUSCHILD, M ;
ROLLNIK, A ;
SCHREIBER, S ;
WUNSCH, B ;
BREUKER, H ;
HEUER, RD ;
LUDWIG, J ;
MOHR, W ;
ROHNER, F ;
RUNGE, K ;
SCHAILE, D ;
SCHAILE, O ;
STIER, HE ;
WAHL, C ;
BOCK, P ;
DIECKMANN, A ;
GARY, JW ;
HEINTZE, J ;
IGOKEMENES, P ;
LENNERT, P ;
VONDERSCHMITT, H ;
WAGNER, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 283 (03) :492-501
[9]   THE OPAL JET CHAMBER FULL SCALE PROTOTYPE [J].
FISCHER, HM ;
HAUSCHILD, M ;
HARTMANN, H ;
HEGERATH, A ;
BOERNER, H ;
BURCKHART, HJ ;
DITTMAR, M ;
HAMMARSTROM, R ;
HEUER, RD ;
MAZZONE, L ;
MICHELINI, A ;
RUNOLFSSON, O ;
SCHAILE, D ;
ULDRY, M ;
VAVRA, J ;
WEISZ, S ;
WICHT, P ;
ZANKEL, K ;
KOLPIN, R ;
LUDWIG, J ;
MOHR, W ;
ROHNER, F ;
ROSER, H ;
RUNGE, K ;
SCHAILE, O ;
SCHWARZ, J ;
STIER, HE ;
WELTIN, A ;
BOCK, P ;
HEINTZE, J ;
IGOKEMENES, P ;
LENNERT, P ;
RUSNIAK, R ;
VONWALTER, P ;
WAGNER, A ;
ZIMMER, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 252 (2-3) :331-342
[10]   UNCERTAINTIES IN TRACK MOMENTUM AND DIRECTION, DUE TO MULTIPLE SCATTERING AND MEASUREMENT ERRORS [J].
GLUCKSTERN, RL .
NUCLEAR INSTRUMENTS & METHODS, 1963, 24 (04) :381-389