FICK-DERIVED HEMODYNAMICS - OXYGEN-CONSUMPTION MEASURED DIRECTLY VS OXYGEN-CONSUMPTION CALCULATED FROM CO-2 PRODUCTION UNDER STEADY-STATE AND DYNAMIC CONDITIONS

被引:14
作者
COHEN, IL
ROBERTS, KW
PERKINS, RJ
FEUSTEL, PJ
SHAH, DM
机构
[1] Department of Surgery, Albany Medical College, Albany
关键词
D O I
10.1378/chest.102.4.1124
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Indirect calorimetry is being used increasingly as a tool for hemodynamic monitoring via the Fick equation. This investigation was undertaken to examine the use of carbon dioxide elimination (Vco2A) and related respiratory quotient (RQ(A)) to calculate oxygen uptake (Vo2A) and estimate oxygen consumption (Vo2) during steady-state and dynamic hemodynamic conditions. Nine patients undergoing abdominal aortic surgery were studied intraoperatively and Fick-derived hemodynamic measurements were made using a monitoring system employing indirect calorimetry, pulse oximetry, and pulmonary artery oximetry. Comparisons were made between measured Vo2A and calculated Vo2A derived from the Vco2A and the initial RQ(A) (RQ(i)), which is assumed not to change. Prior to aortic crossclamping (steady state), there were no significant differences between the measured and calculated methods with respect to oxygen consumption (184+/-24 ml/min vs 185+/-17 ml/min), oxygen delivery (753+/-141 ml/min vs 769+/-178 ml/min), and cardiac output (4.7+/-0.6 L/min vs 4.7+/-0.7 L/min). However, immediately following aortic unclamping (dynamic state), the RQ(A) changed precipitously from the baseline RQ(i). Consequently, significant differences between the measured and calculated methods were noted in oxygen uptake (213+/-41 ml/min vs 193+/-25 ml/min, p<0.001), oxygen delivery (780+/-297 ml/min vs 716+/-296 ml/min, p<0.001), and cardiac output (5.8+/-2.2 L/min vs 5.3+/-1.8 L/min, p<0.001). Additionally, following unclamping, the peak Vo2A was 242+/-49 compared with a cVo2A of only 198+/-22 (p<0.01). We conclude that the use of Vco2A to calculate Vo2A may lead to erroneous measurements under dynamic conditions, such as unclamping of the abdominal aorta.
引用
收藏
页码:1124 / 1127
页数:4
相关论文
共 22 条
[1]   NUTRITION FOR THE PATIENT WITH RESPIRATORY-FAILURE - GLUCOSE VS FAT [J].
ASKANAZI, J ;
NORDENSTROM, J ;
ROSENBAUM, SH ;
ELWYN, DH ;
HYMAN, AI ;
CARPENTIER, YA ;
KINNEY, JM .
ANESTHESIOLOGY, 1981, 54 (05) :373-377
[2]  
BILEN Z, 1990, 6TH INT S CARD URG R
[3]   THE EFFECTS OF A FLUCTUATING FIO2 ON METABOLIC MEASUREMENTS IN MECHANICALLY VENTILATED PATIENTS [J].
BROWNING, JA ;
LINBERG, SE ;
TURNEY, SZ ;
CHODOFF, P .
CRITICAL CARE MEDICINE, 1982, 10 (02) :82-85
[4]   CARDIAC-OUTPUT DETERMINATION - THERMODILUTION VERSUS A NEW COMPUTERIZED FICK METHOD [J].
CARPENTER, JP ;
NAIR, S ;
STAW, I .
CRITICAL CARE MEDICINE, 1985, 13 (07) :576-579
[5]  
Christiansen J, 1914, J PHYSIOL-LONDON, V48, P244
[6]  
COHEN I, 1990, American Review of Respiratory Disease, V141, pA583
[7]  
COHEN IL, 1991, ACP-APPL CARDIOPUL P, V3, P351
[8]  
DAMASK MC, 1984, ARCH SURG-CHICAGO, V119, P1332
[9]   CONTINUOUS FICK CARDIAC-OUTPUT COMPARED TO THERMODILUTION CARDIAC-OUTPUT [J].
DAVIES, GG ;
JEBSON, PJR ;
GLASGOW, BM ;
HESS, DR .
CRITICAL CARE MEDICINE, 1986, 14 (10) :881-885
[10]  
FEUSTEL PJ, 1991, CHEST, V100, pS123