ELECTROCATALYSIS AND FLOW-INJECTION ANALYSIS OF HYDROGEN-PEROXIDE AT A CHEMICALLY MODIFIED ELECTRODE

被引:39
作者
GAO, ZQ [1 ]
IVASKA, A [1 ]
LI, P [1 ]
LUI, KZ [1 ]
YANG, JJ [1 ]
机构
[1] HENAN UNIV,DEPT CHEM,KAIFENG 475001,PEOPLES R CHINA
关键词
AMPEROMETRY; CYCLIC VOLTAMMETRY; FLOW SYSTEM; ELECTROCATALYSIS; HYDROGEN PEROXIDE;
D O I
10.1016/0003-2670(92)85370-L
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A chemically modified electrode for the amperometric detection of hydrogen peroxide is described. By electrode-position of a copper heptacyanonitrosylferrate(II) (CuHNF) film on the surface of a glassy carbon electrode, the overvoltages for both oxidation and reduction of hydrogen peroxide can be drastically decreased. Cyclic voltammetry at the resulting modified electrode reveals the persence of two pairs of redox peaks corresponding to the Cu(I)-Cu(II) and Fe(II)(CN)5NO-Fe(III)(CN)5NO redox couples, respectively. The modified electrode is less prone to fouling and shows enhanced sensitivity for hydrogen peroxide. Various electrochemical response characteristics were investigated. When applied as an electrochemical sensor in a flow-injection system, the modified electrode permitted detection of hydrogen peroxide at lower potentials than at the unmodified electrode surface. This greatly improved the selectivity. A linear amperometric response range with hydrogen peroxide was obtained between 0.4-mu-M and 1 mM. The relative standard deviation for 30 repetitive injections with a 10-mu-M hydrogen peroxide solution over a 30-min period was less than 4%.
引用
收藏
页码:211 / 218
页数:8
相关论文
共 27 条
[1]  
APPLEBY AJ, 1978, J ELECTROANAL CHEM, V692, P15
[2]  
Bard A. J., 2001, ELECTROCHEMICAL METH, V2nd, P50
[3]   COVALENT LINKAGE OF GLUCOSE-OXIDASE ON MODIFIED GLASSY-CARBON ELECTRODES - KINETIC PHENOMENA [J].
BOURDILLON, C ;
BOURGEOIS, JP ;
THOMAS, D .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1980, 102 (12) :4231-4235
[4]   MECHANISM OF THE MEDIATED REDUCTION OF HYDROGEN-PEROXIDE AT AN ELECTRODE MODIFIED WITH A FILM CONTAINING A BASIC FORM OF IRIDIUM OXIDE [J].
COX, JA ;
JAWORSKI, RK .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 281 (1-2) :163-170
[5]   VOLTAMMETRIC REDUCTION AND DETERMINATION OF HYDROGEN-PEROXIDE AT AN ELECTRODE MODIFIED WITH A FILM CONTAINING PALLADIUM AND IRIDIUM [J].
COX, JA ;
JAWORSKI, RK .
ANALYTICAL CHEMISTRY, 1989, 61 (19) :2176-2178
[6]  
GAO Z, 1990, THESIS WUHAN U
[8]   A GLUCOSE SENSOR BASED ON THE ADSORPTION OF GLUCOSE ON A PALLADIUM GOLD MODIFIED CARBON ELECTRODE [J].
GORTON, L ;
JONSSON, G .
JOURNAL OF MOLECULAR CATALYSIS, 1986, 38 (1-2) :157-159
[9]  
Guilbault GG, 1976, HDB ENZYMATIC METHOD
[10]   AN ELECTROCHEMICAL SENSOR FOR HYDROGEN-PEROXIDE BASED ON PEROXIDASE ADSORBED ON A SPECTROGRAPHIC GRAPHITE ELECTRODE [J].
JONSSON, G ;
GORTON, L .
ELECTROANALYSIS, 1989, 1 (05) :465-468