FIELD-EVALUATION OF THE SULFUR CHEMILUMINESCENCE DETECTOR

被引:38
作者
BENNER, RL [1 ]
STEDMAN, DH [1 ]
机构
[1] UNIV DENVER,DEPT CHEM,DENVER,CO 80208
关键词
D O I
10.1021/es00080a021
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A field evaluation of the sulfur chemiluminescence detector (SCD) as a real-time total atmospheric sulfur detector is presented. The SCD was installed in a monitoring trailer along with a flame photometric detector (FPD), fluorescent SO2 monitor (Fluor), and a suite of other monitoring instruments. The performance of the analyzers was compared for (1) baseline stability, (2) response stability, (3) interferences, (4) sensitivity, and (5) environmental temperature effects. The SCD exhibited the best baseline stability and sensitivity, but had a drift in sensitivity larger than the other analyzers. The FPD and Fluor both showed interference effects, but none were observed for the SCD. Ambient temperature variations altered both the baseline and sensitivity of the FPD and the sensitivity of the Fluor. The SCD showed no ambient temperature dependence on either the baseline or sensitivity. © 1990, American Chemical Society. All rights reserved.
引用
收藏
页码:1592 / 1596
页数:5
相关论文
共 10 条
[1]   UNIVERSAL SULFUR DETECTION BY CHEMI-LUMINESCENCE [J].
BENNER, RL ;
STEDMAN, DH .
ANALYTICAL CHEMISTRY, 1989, 61 (11) :1268-1271
[2]   SULFUR-SELECTIVE DETECTION WITH THE FPD - CURRENT ENIGMAS, PRACTICAL USAGE, AND FUTURE-DIRECTIONS [J].
FARWELL, SO ;
BARINAGA, CJ .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1986, 24 (11) :483-494
[3]   AN EXPERIMENTAL-STUDY OF SULFUR AND NOX FLUXES OVER GRASSLAND [J].
HICKS, BB ;
WESELY, ML ;
COULTER, RL ;
HART, RL ;
DURHAM, JL ;
SPEER, R ;
STEDMAN, DH .
BOUNDARY-LAYER METEOROLOGY, 1986, 34 (1-2) :103-121
[4]   QUANTITATION OF THE LOSSES OF GASEOUS SULFUR-COMPOUNDS TO ENCLOSURE WALLS [J].
KUSTER, WC ;
GOLDAN, PD .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1987, 21 (08) :810-815
[5]   MEASUREMENT OF BIOGENIC SULFUR EMISSIONS FROM SOILS AND VEGETATION - APPLICATION OF DYNAMIC ENCLOSURE METHODS WITH NATUSCH FILTER AND GC/FPD ANALYSIS [J].
LAMB, B ;
WESTBERG, H ;
ALLWINE, G ;
BAMESBERGER, L ;
GUENTHER, A .
JOURNAL OF ATMOSPHERIC CHEMISTRY, 1987, 5 (04) :469-491
[6]   TECHNIQUES FOR DETERMINING CHEMICAL COMPOSITION OF AEROSOL SULFUR-COMPOUNDS [J].
NEWMAN, L .
ATMOSPHERIC ENVIRONMENT, 1978, 12 (1-3) :113-125
[7]  
SEINFELD JH, 1986, ATMOSPHERIC CHEM PHY, P36
[8]   ANALYSIS OF SULFUR-COMPOUNDS BY CAPILLARY COLUMN GAS-CHROMATOGRAPHY WITH SULFUR CHEMI-LUMINESCENCE DETECTION [J].
SHEARER, RL ;
ONEAL, DL ;
RIOS, R ;
BAKER, MD .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1990, 28 (01) :24-28
[9]   WATER INTERFERENCE OF PULSED FLUORESCENCE SO2 MONITOR [J].
STELSON, AW ;
BAO, XP .
JAPCA-THE INTERNATIONAL JOURNAL OF AIR POLLUTION CONTROL AND HAZARDOUS WASTE MANAGEMENT, 1988, 38 (04) :420-420
[10]   FIELD EXPERIENCE WITH AMBIENT-LEVEL FLAME-PHOTOMETRIC SULFUR DETECTORS [J].
WEBER, D ;
OLSEN, KB ;
LUDWICK, JD .
TALANTA, 1980, 27 (08) :665-668