APPLICATION OF THE CONVOLUTION METHOD FOR CALCULATION OF OUTPUT FACTORS FOR THERAPY PHOTON BEAMS

被引:67
作者
AHNESJO, A
KNOOS, T
MONTELIUS, A
机构
[1] HELAX AB,S-75147 UPPSALA,SWEDEN
[2] UNIV LUND,ALLAMANNA SJUKHUSET,DEPT RADIAT PHYS,S-21401 MALMO,SWEDEN
[3] UNIV HOSP UPPSALA,DEPT HOSP PHYS,UPPSALA,SWEDEN
关键词
OUTPUT FACTOR; MONITOR UNIT; COLLIMATOR SCATTER; DOSE COMPUTATION; CONVOLUTION METHOD; TREATMENT PLANNING; PHOTON BEAM DOSIMETRY; MULTILEAF COLLIMATOR;
D O I
10.1118/1.596859
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The output factor for a therapy photon beam is defined as the dose per monitor unit relative to the dose per monitor unit in a reference field. Convolution models for photon dose calculations yield the dose in units normalized to the incident energy fluence with phantom scatter intrinsically modeled. Output factors calculated with the convolution method as the dose per unit energy fluence relative to the calculated dose per unit energy fluence in a reference field could deviate as much as 5% if corrections are not made for perturbations due to treatment head scatter. Significant perturbations are particles backscattered from the collimators to the monitor and photons forward scattered from the filter and collimators in the treatment head. The forward scatter adds an "unmonitored" contribution to the total energy fluence of the beam. A model is developed that describes the field size dependence of these perturbations for conversion of output factors, calculated with the convolution method, to machine output factors as an integrated part in treatment planning. The necessary machine characteristics are derived from measurements of the output in air for a limited set of field sizes. The method has been tested using five different multileaf collimated irregular fields at 6 MV and for a large set of rectangular fields at 5, 6, and 18 MV and found to predict output factors with an accuracy better than 1%.
引用
收藏
页码:295 / 301
页数:7
相关论文
共 17 条
[1]   A PENCIL BEAM MODEL FOR PHOTON DOSE CALCULATION [J].
AHNESJO, A ;
SAXNER, M ;
TREPP, A .
MEDICAL PHYSICS, 1992, 19 (02) :263-273
[2]   COLLAPSED CONE CONVOLUTION OF RADIANT ENERGY FOR PHOTON DOSE CALCULATION IN HETEROGENEOUS MEDIA [J].
AHNESJO, A .
MEDICAL PHYSICS, 1989, 16 (04) :577-592
[3]   DETERMINATION OF EFFECTIVE BREMSSTRAHLUNG SPECTRA AND ELECTRON CONTAMINATION FOR PHOTON DOSE CALCULATIONS [J].
AHNESJO, A ;
ANDREO, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (10) :1451-1464
[4]   CALCULATION AND APPLICATION OF POINT SPREAD FUNCTIONS FOR TREATMENT PLANNING WITH HIGH-ENERGY PHOTON BEAMS [J].
AHNESJO, A ;
ANDREO, P ;
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (01) :49-56
[5]  
[Anonymous], 1983, MED PHYS, V10, P741
[6]   A PHOTON DOSE DISTRIBUTION MODEL EMPLOYING CONVOLUTION CALCULATIONS [J].
BOYER, A ;
MOK, E .
MEDICAL PHYSICS, 1985, 12 (02) :169-177
[7]   TISSUE STANDARD RATIOS FOR IRREGULARLY SHAPED RADIOTHERAPY FIELDS [J].
HOUNSELL, AR ;
WILKINSON, JM .
BRITISH JOURNAL OF RADIOLOGY, 1990, 63 (752) :629-634
[9]   OUTPUT FACTOR CONSTITUENTS OF A HIGH-ENERGY PHOTON-BEAM [J].
LUXTON, G ;
ASTRAHAN, MA .
MEDICAL PHYSICS, 1988, 15 (01) :88-91
[10]   A CONVOLUTION METHOD OF CALCULATING DOSE FOR 15-MV X-RAYS [J].
MACKIE, TR ;
SCRIMGER, JW ;
BATTISTA, JJ .
MEDICAL PHYSICS, 1985, 12 (02) :188-196