A COMPARISON OF CORNEAL ENDOTHELIAL CHANGES AFTER USE OF HEALON OR VISCOAT DURING PHACOEMULSIFICATION

被引:77
作者
KOCH, DD
LIU, JF
GLASSER, DB
MERIN, LM
HAFT, E
机构
[1] PATUXENT MED GRP,COLUMBIA,MD
[2] BAYLOR COLL MED,CULLEN EYE INST,DEPT OPHTHALMOL,HOUSTON,TX 77030
[3] UNIV MARYLAND,SCH MED,DEPT OPHTHALMOL,BALTIMORE,MD 21201
关键词
D O I
10.1016/S0002-9394(14)73923-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We conducted a prospective, randomized trial comparing the endothelial protective effects of Healon (Kabi Pharmacia Ophthalmics, Inc., Monrovia, California) and Viscoat (Alcon Surgical, Inc., Ft. Worth, Texas) in 59 eyes of 59 patients undergoing iris-plane or posterior-chamber phacoemulsification with posterior-chamber lens implantation. We evaluated postoperative central and superior changes in corneal thickness and corneal endothelial cell density, coefficient of variation in cell size, and percentage of hexagons. In the overall series, at one day postoperatively, corneal thickness increased 17% centrally and superiorly in eyes receiving Healon compared to 12% centrally and 11% superiorly in eyes receiving Viscoat (P < .05). Sixteen weeks postoperatively, superior endothelial cell loss was 11.6% in eyes receiving Healon compared to 2.1% in eyes receiving Viscoat (P < .01). In the iris-plane phacoemulsification group, superior cell loss at week 16 was 13.8% in eyes receiving Healon and 0.5% in eyes receiving Viscoat (P < .04). In the posterior-chamber phacoemulsification group, there were no significant differences between the Healon and Viscoat subgroups. Comparing the surgical techniques, in the Healon group, central cell loss at week 16 was 13.8% in the iris-plane phacoemulsification subgroup and 0.6% in the posterior-chamber phacoemulsification subgroup (P < .03), and coefficient of variation in cell size increased 3.7% in the iris-Plane subgroup and decreased 6.8% in the posterior-chamber subgroup (P < .04). In the Viscoat group, there were no significant differences between surgical techniques at week 16. Viscoat provided greater corneal endothelial protection than Healon during iris-plane phacoemulsification. In eyes receiving Healon, posterior-chamber phacoemulsification resulted in less corneal endothelial trauma than the iris-plane technique.
引用
收藏
页码:188 / 201
页数:14
相关论文
共 18 条
[1]  
ALPAR JJ, 1988, OPHTHALMIC SURG LAS, V19, P636
[2]  
BOTHNER H, 1989, VISCOELASTIC MATERIA, P3
[3]   USE OF SPECULAR PHOTOMICROGRAPHY WITH A NEW TYPE OF FILM [J].
CARLSON, AN ;
MERIN, LM ;
WILHELMUS, KR ;
JONES, DB .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1988, 105 (02) :217-218
[4]   POSITIVE CORRELATION OF CORNEAL THICKNESS AND ENDOTHELIAL-CELL LOSS - SERIAL MEASUREMENTS AFTER CATARACT-SURGERY [J].
CHENG, H ;
BATES, AK ;
WOOD, L ;
MCPHERSON, K .
ARCHIVES OF OPHTHALMOLOGY, 1988, 106 (07) :920-922
[5]  
CRAIG MT, 1909, J CATARACT REFR SURG, V16, P597
[7]   PROTECTIVE EFFECTS OF VISCOUS SOLUTIONS IN PHACOEMULSIFICATION AND TRAUMATIC LENS IMPLANTATION [J].
GLASSER, DB ;
KATZ, HR ;
BOYD, JE ;
LANGDON, JD ;
SHOBE, SL ;
PEIFFER, RL .
ARCHIVES OF OPHTHALMOLOGY, 1989, 107 (07) :1047-1051
[8]   ENDOTHELIAL PROTECTION AND VISCOELASTIC RETENTION DURING PHACOEMULSIFICATION AND INTRAOCULAR-LENS IMPLANTATION [J].
GLASSER, DB ;
OSBORN, DC ;
NORDEEN, JF ;
MIN, YI .
ARCHIVES OF OPHTHALMOLOGY, 1991, 109 (10) :1438-1440
[9]  
GLASSER DB, 1986, ARCH OPHTHALMOL-CHIC, V104, P64
[10]  
HAMMER ME, 1984, INVEST OPHTH VIS SCI, V25, P1329