ACTIVITY DISTRIBUTION OF A CO-60 TELETHERAPY SOURCE

被引:5
作者
JAFFRAY, DA [4 ]
MUNRO, P
BATTISTA, JJ
FENSTER, A
机构
[1] LONDON REG CANC CTR,LONDON N6A 4L6,ONTARIO,CANADA
[2] ROBARTS RES INST,IMAGING RES LABS,LONDON N6A 5K8,ONTARIO,CANADA
[3] UNIV WESTERN ONTARIO,DEPT RADIOL,LONDON N6A 3K7,ONTARIO,CANADA
[4] UNIV WESTERN ONTARIO,DEPT MED BIOPHYS,LONDON N6A 3K7,ONTARIO,CANADA
关键词
CO-60; STRIP INTEGRAL; PORTAL IMAGING; SPATIAL RESOLUTION;
D O I
10.1118/1.596672
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In the course of quantifying the effect of radiation source size on the spatial resolution of portal images, a concentric ring structure in the activity distribution of a Cobalt-60 teletherapy source has been observed. The activity distribution was measured using a strip integral technique and confirmed independently by a contact radiograph of an identical but inactive source replica. These two techniques suggested that this concentric ring structure is due to the packing configuration of the small Co-60 pellets that constitute the source. The source modulation transfer function (MTF) showed that this ring structure has a negligible influence on the spatial resolution of therapy images when compared to the effect of the large size of the Co-60 source.
引用
收藏
页码:288 / 291
页数:4
相关论文
共 21 条
[1]  
BAILY NA, 1980, INT J RADIAT ONCOL, V6, P935, DOI 10.1016/0360-3016(80)90341-7
[2]   PRINCIPLES OF COMPUTER-ASSISTED TOMOGRAPHY (CAT) IN RADIOGRAPHIC AND RADIOISOTOPIC IMAGING [J].
BROOKS, RA ;
DICHIRO, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :689-732
[3]   WEEKLY LOCALIZATION FILMS AND DETECTION OF FIELD PLACEMENT ERRORS [J].
BYHARDT, RW ;
COX, JD ;
HORNBURG, A ;
LIERMANN, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1978, 4 (9-10) :881-887
[4]   IMMOBILIZATION ERROR - SOME THEORETICAL CONSIDERATIONS [J].
GOITEIN, M ;
BUSSE, J .
RADIOLOGY, 1975, 117 (02) :407-412
[5]   THE DAILY REPRODUCIBILITY OF LARGE, COMPLEX-SHAPED RADIOTHERAPY FIELDS TO THE THORAX AND NECK [J].
GRIFFITHS, SE ;
PEARCEY, RG .
CLINICAL RADIOLOGY, 1986, 37 (01) :39-41
[6]   MONTE-CARLO SIMULATION OF A CO-60 BEAM [J].
HAN, K ;
BALLON, D ;
CHUI, C ;
MOHAN, R .
MEDICAL PHYSICS, 1987, 14 (03) :414-419
[7]  
HUESMAN RH, 1977, L BERKELEY LABORATOR, V214
[8]   ACCURACY IN RADIATION-FIELD ALIGNMENT IN HEAD AND NECK-CANCER - A PROSPECTIVE-STUDY [J].
HUIZENGA, H ;
LEVENDAG, PC ;
DEPORRE, PMZR ;
VISSER, AG .
RADIOTHERAPY AND ONCOLOGY, 1988, 11 (02) :181-187
[9]  
KINZIE JJ, 1983, CANCER, V52, P2223, DOI 10.1002/1097-0142(19831215)52:12<2223::AID-CNCR2820521209>3.0.CO
[10]  
2-D