LONG-TERM RESULTS OF UNCEMENTED ALUMINA ACETABULAR IMPLANTS

被引:101
作者
BOEHLER, M
KNAHR, K
PLENK, H
WALTER, A
SALZER, M
SCHREIBER, V
机构
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1994年 / 76B卷 / 01期
关键词
D O I
10.1302/0301-620X.76B1.8300682
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We report the clinical and tribological performance of 67 ceramic acetabular prostheses implanted between 1976 and 1979 without bone cement. They articulated with ceramic femoral heads mounted on metal femoral stems. After a mean elapsed period of 144 months, 59 sockets were radiographically stable but two showed early signs and six showed late signs of loosening. Four of the loose sockets have been revised. Histological analysis of the retrieved tissue showed a fibrous membrane around all the implants, with fibrocartilage in some. There was no bone ingrowth, and the fibrous membrane was up to 6 mm thick and infiltrated with lymphocytes, plasma cells, and macrophages. Intra- and extracellular birefringent wear particles were seen. Tribological analysis showed total wear rates in two retrieved alumina-on-alumina joints of 2.6 mu m per year in a stable implant and 68 mu m in a loose implant. Survival analysis showed a revision rate of 12.4 % at 136 months.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 28 条
[1]   COMPARATIVE INVESTIGATIONS OF REGIONAL LYMPH-NODES AND PSEUDOCAPSULES AFTER IMPLANTATION OF JOINT ENDOPROSTHESES [J].
BOS, I ;
JOHANNISSON, R ;
LOHRS, U ;
LINDNER, B ;
SEYDEL, U .
PATHOLOGY RESEARCH AND PRACTICE, 1990, 186 (06) :707-716
[2]  
BOUTIN P, 1972, REV CHIR ORTHOP, V58, P229
[3]   PROPERTIES REQUIRED OF BIOCERAMICS FOR ARTIFICIAL JOINTS [J].
DORRE, E ;
BEUTLER, H ;
GEDULDIG, D .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1975, 83 (03) :269-278
[4]   5 YEARS EXPERIENCE WITH CERAMIC-METAL-COMPOSITE HIP ENDOPROSTHESES .1. CLINICAL-EVALUATION [J].
GRISS, P ;
HEIMKE, G .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1981, 98 (03) :157-164
[5]   BIOMECHANICALLY INDUCED TISSUE-REACTIONS AFTER AI2O3-CERAMIC HIP-JOINT REPLACEMENT - EXPERIMENTAL AND EARLY CLINICAL RESULTS [J].
GRISS, P ;
SILBER, R ;
MERKLE, B ;
HAEHNER, K ;
HEIMKE, G ;
KREMPIEN, B .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1976, 10 (04) :519-528
[6]  
HOFFINGER SA, 1991, ORTHOPEDICS, V14, P523
[7]   A RAT MODEL OF RESORPTION OF BONE AT THE CEMENT-BONE INTERFACE IN THE PRESENCE OF POLYETHYLENE WEAR PARTICLES [J].
HOWIE, DW ;
VERNONROBERTS, B ;
OAKESHOTT, R ;
MANTHEY, B .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (02) :257-263
[8]   ATTACHMENT OF PROSTHESES TO MUSCULOSKELETAL SYSTEM BY TISSUE INGROWTH AND MECHANICAL INTERLOCKING [J].
HULBERT, SF ;
COOKE, FW ;
KLAWITTER, JJ ;
LEONARD, RB ;
SAUER, BW ;
MOYLE, DD ;
SKINNER, HB .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1973, 7 (03) :1-23
[9]   NONPARAMETRIC-ESTIMATION FROM INCOMPLETE OBSERVATIONS [J].
KAPLAN, EL ;
MEIER, P .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1958, 53 (282) :457-481
[10]   SURVIVAL ANALYSIS OF AN UNCEMENTED CERAMIC ACETABULAR COMPONENT IN TOTAL HIP-REPLACEMENT [J].
KNAHR, K ;
BOHLER, M ;
FRANK, P ;
PLENK, H ;
SALZER, M .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1987, 106 (05) :297-300