LONGITUDINAL ASSESSMENT OF AMNIOTIC-FLUID INDEX

被引:37
作者
NWOSU, EC [1 ]
WELCH, CR [1 ]
MANASSE, PR [1 ]
WALKINSHAW, SA [1 ]
机构
[1] UNIV LIVERPOOL, DEPT OBSTET & GYNAECOL, LIVERPOOL L69 3BX, ENGLAND
来源
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY | 1993年 / 100卷 / 09期
关键词
D O I
10.1111/j.1471-0528.1993.tb14305.x
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective To derive a longitudinal gestational reference range for amniotic fluid index and to compare it with the established cross-sectional reference range. Design Longitudinal prospective study. Setting Liverpool Maternity Hospital and Mill Road Maternity Hospital, both teaching hospitals in central Liverpool. Subjects One hundred and fifteen pregnant women, in whom the expected date by the last menstrual period and ultrasound scan at 18 to 19 weeks were in agreement by seven days, were recruited. They were divided into two groups and scanned at four weekly intervals as follows: Group A: scanned at 20,24,28,32, 36, 40; and Group B: scanned at 22, 26, 30, 34, 38, 42. Results Amniotic fluid index varies with gestation, rising from early gestation to peak at 30 weeks and then falling from 36 to 42 weeks. Comparison of our reference range with that of Moore and Cayle (1990) shows obvious differences at the lower limit. Conclusion We have established a normal longitudinal reference range for the amniotic fluid index. Our ranges, derived from longitudinal data, would seem a more appropriate reference than the established reference ranges derived from cross-sectional data. In particular, the differences at the lower limits may have considerable clinical implication in the use of amniotic fluid index in the prediction of fetal compromise.
引用
收藏
页码:816 / 819
页数:4
相关论文
共 23 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   LIMITATIONS OF USING MAXIMUM VERTICAL POCKET AND OTHER SONOGRAPHIC EVALUATIONS OF AMNIOTIC-FLUID VOLUME TO PREDICT FETAL GROWTH - TECHNICAL OR PHYSIOLOGICAL [J].
BOTTOMS, SF ;
WELCH, RA ;
ZADOR, IE ;
SOKOL, RJ .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1986, 155 (01) :154-158
[3]   NORMAL AMNIOTIC-FLUID VOLUME CHANGES THROUGHOUT PREGNANCY [J].
BRACE, RA ;
WOLF, EJ .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1989, 161 (02) :382-388
[4]   STATISTICAL-METHODS FOR ASSESSING OBSERVER VARIABILITY IN CLINICAL MEASURES [J].
BRENNAN, P ;
SILMAN, A .
BMJ-BRITISH MEDICAL JOURNAL, 1992, 304 (6840) :1491-1494
[5]   ULTRASOUND EVALUATION OF AMNIOTIC-FLUID VOLUME .1. THE RELATIONSHIP OF MARGINAL AND DECREASED AMNIOTIC-FLUID VOLUMES TO PERINATAL OUTCOME [J].
CHAMBERLAIN, PF ;
MANNING, FA ;
MORRISON, I ;
HARMAN, CR ;
LANGE, IR .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1984, 150 (03) :245-249
[6]  
CHAUHAN SP, 1991, J REPROD MED, V36, P801
[7]   THE VALUE OF ULTRASOUND MEASUREMENT OF AMNIOTIC-FLUID VOLUME IN THE MANAGEMENT OF PROLONGED PREGNANCIES [J].
CROWLEY, P ;
OHERLIHY, C ;
BOYLAN, P .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1984, 91 (05) :444-448
[8]  
Gadd R L, 1966, J Obstet Gynaecol Br Commonw, V73, P11, DOI 10.1111/j.1471-0528.1966.tb05114.x
[9]   GROWTH OF TOTAL INTRAUTERINE, INTRA-AMNIOTIC AND PLACENTAL VOLUME IN NORMAL SINGLETON PREGNANCY MEASURED BY ULTRASOUND [J].
GEIRSSON, RT ;
OGSTON, SA ;
PATEL, NB ;
CHRISTIE, AD .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1985, 92 (01) :46-53
[10]   EVALUATION OF FETAL RENAL FUNCTION IN A CHRONIC SHEEP PREPARATION [J].
GRESHAM, EL ;
BATTAGLIA, FC ;
RANKIN, JHG ;
MAKOWSKI, EL ;
MESCHIA, G .
JOURNAL OF CLINICAL INVESTIGATION, 1972, 51 (01) :149-+