MICROBOLOMETERS FOR INFRARED DETECTION

被引:78
作者
HWANG, TL [1 ]
SCHWARZ, SE [1 ]
RUTLEDGE, DB [1 ]
机构
[1] UNIV CALIF BERKELEY,COMP SCI & ELECTR RES LAB,BERKELEY,CA 94720
关键词
D O I
10.1063/1.90669
中图分类号
O59 [应用物理学];
学科分类号
摘要
We describe a novel room-temperature detector for the wavelength range 10-1000 μm. This detector consists of a thin bismuth bolometer film with dimensions much smaller than a wavelength. The small size of the detector results in reduced NEP and faster response. A video NEP of 1.6×10 -10 W/Hz1/2 is obtained at 119 μm, remaining within a factor of 10 of this value for modulation frequencies up to 25 MHz. When used as a mixer, the device is predicted to have an NEP of 3.5×10-18 W/Hz. It is easily fabricated with conventional planar processing techniques and can be replicated in arrays. The device is expected to be most useful when the radiation to be detected is spatially coherent.
引用
收藏
页码:773 / 776
页数:4
相关论文