DESCRIPTION OF THE DEFORMATION OF THE LEFT-VENTRICLE BY A KINEMATIC MODEL

被引:92
作者
ARTS, T [1 ]
HUNTER, WC [1 ]
DOUGLAS, A [1 ]
MUIJTJENS, AMM [1 ]
RENEMAN, RS [1 ]
机构
[1] JOHNS HOPKINS UNIV,DEPT BIOMED ENGN,BALTIMORE,MD 21218
关键词
D O I
10.1016/0021-9290(92)90068-C
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A model of left ventricular (LV) kinematics is essential to identify the fundamental physiological modes of LV deformation during a complete cardiac cycle as observed from the motion of a finite number of markers embedded in the LV wall. Kinematics can be described by a number of modes of motion and deformation in succession. An obvious mode of LV deformation is the ejection of cavity volume while the wall thickens. In the more sophisticated model of LV kinematics developed here, seven time-dependent parameters were used to describe not only volume change but also torsion and shape changes throughout the cardiac cycle. Rigid-body motion required another six parameters. The kinematic model employed a deformation field that had no singularities within the myocardium, and all parameters describing the modes of deformation were dimensionless. Note that torsion, volume and symmetric shape changes all require the definition of a cardiac coordinate system, which has generally been related to the measured cardiac geometry by reference to approximate anatomical landmarks. However, in the present study the coordinate system was positioned objectively by a least-squares fit of the kinematic model to the measured motion of markers. Theoretically, at least five markers are needed to find a unique set of parameters. In a computer simulation for 6, 14 and 100 markers, the stability of the parameter estimates was investigated. In a realistic case of normal cardiac deformation, 60 frames in time, 14 markers and a measuring error of +/- 0.3 mm (S.D.), the standard error in the determination of the location of the coordinate origin and the direction of the torsion axis were +/- 0.24 mm and +/- 0.015 rad, respectively. For a simulated 100 g LV, errors per frame in the estimated parameters were: +/- 0.6 ml. in volume, +/- 0.005 rad in torsion, and +/- 0.002 in long-axis shape. Furthermore, in an experimental trial the kinematic model described the motion of 14 radiopaque markers implanted in a canine LV with a small r.m.s. error in the fit to each marker: +/- 0.2 mm during ejection and + 0.5 mm in the rest of the cycle. The time courses of all 13 kinematic parameters were obtained with high signal/noise ratios. During ejection, the major modes of deformation were torsion and axially symmetric shape change in conjunction with volume change.
引用
收藏
页码:1119 / 1127
页数:9
相关论文
共 22 条
  • [1] TORSION OF THE LEFT-VENTRICLE DURING THE EJECTION PHASE IN THE INTACT DOG
    ARTS, T
    MEERBAUM, S
    RENEMAN, RS
    CORDAY, E
    [J]. CARDIOVASCULAR RESEARCH, 1984, 18 (03) : 183 - 193
  • [2] DYNAMICS OF LEFT-VENTRICULAR WALL AND MITRAL-VALVE MECHANICS - A MODEL STUDY
    ARTS, T
    RENEMAN, RS
    [J]. JOURNAL OF BIOMECHANICS, 1989, 22 (03) : 261 - 271
  • [3] EPICARDIAL DEFORMATION AND LEFT-VENTRICULAR WALL MECHANICS DURING EJECTION IN THE DOG
    ARTS, T
    VEENSTRA, PC
    RENEMAN, RS
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1982, 243 (03): : H379 - H390
  • [4] A MODEL OF THE MECHANICS OF THE LEFT-VENTRICLE
    ARTS, T
    RENEMAN, RS
    VEENSTRA, PC
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1979, 7 (3-4) : 299 - 318
  • [5] DEPENDENCE OF LEFT-VENTRICULAR TWIST-RADIAL SHORTENING RELATIONS ON CARDIAC CYCLE PHASE
    BEYAR, R
    YIN, FCP
    HAUSKNECHT, M
    WEISFELDT, ML
    KASS, DA
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (04): : H1119 - H1126
  • [6] A COMPUTER STUDY OF THE LEFT-VENTRICULAR PERFORMANCE BASED ON FIBER STRUCTURE, SARCOMERE DYNAMICS, AND TRANSMURAL ELECTRICAL PROPAGATION VELOCITY
    BEYAR, R
    SIDEMAN, S
    [J]. CIRCULATION RESEARCH, 1984, 55 (03) : 358 - 375
  • [7] NONINVASIVE QUANTIFICATION OF LEFT-VENTRICULAR ROTATIONAL DEFORMATION IN NORMAL HUMANS USING MAGNETIC-RESONANCE-IMAGING MYOCARDIAL TAGGING
    BUCHALTER, MB
    WEISS, JL
    ROGERS, WJ
    ZERHOUNI, EA
    WEISFELDT, ML
    BEYAR, R
    SHAPIRO, EP
    [J]. CIRCULATION, 1990, 81 (04) : 1236 - 1244
  • [8] MECHANICS OF THE LEFT-VENTRICLE
    CHADWICK, RS
    [J]. BIOPHYSICAL JOURNAL, 1982, 39 (03) : 279 - 288
  • [9] MEASUREMENT OF 3-DIMENSIONAL POSITIONS AND MOTIONS OF LARGE NUMBERS OF SPHERICAL RADIOPAQUE MARKERS FROM BIPLANE CINERADIOGRAMS
    GARRISON, JB
    EBERT, WL
    JENKINS, RE
    YIONOULIS, SM
    MALCOM, H
    HEYLER, GA
    SHOUKAS, AA
    MAUGHAN, WL
    SAGAWA, K
    [J]. COMPUTERS AND BIOMEDICAL RESEARCH, 1982, 15 (01): : 76 - 96
  • [10] EFFECT OF VOLUME LOADING, PRESSURE LOADING, AND INOTROPIC STIMULATION ON LEFT-VENTRICULAR TORSION IN HUMANS
    HANSEN, DE
    DAUGHTERS, GT
    ALDERMAN, EL
    INGELS, NB
    STINSON, EB
    MILLER, DC
    [J]. CIRCULATION, 1991, 83 (04) : 1315 - 1326