DIGITAL SIGNAL-PROCESSING CHIP IMPLEMENTATION FOR DETECTION AND ANALYSIS OF INTRACARDIAC ELECTROGRAMS

被引:19
作者
CHIANG, CMJ
JENKINS, JM
DICARLO, LA
机构
[1] MICHIGAN HEART & VASC INST,ANN ARBOR,MI
[2] UNIV MICHIGAN,COLL ENGN,DEPT ELECT ENGN & COMP SCI,ANN ARBOR,MI 48109
[3] ST JOSEPH MERCY HOSP,CARDIAC ELECTROPHYSIOL LAB,ANN ARBOR,MI 48104
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1994年 / 17卷 / 08期
关键词
ARRHYTHMIA; INTRACARDIAC ELECTROGRAM; ANTITACHYCARDIA DEVICE; IMPLANTABLE DEFIBRILLATOR;
D O I
10.1111/j.1540-8159.1994.tb02456.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The adoption of digital signal processing (DSP) microchips for detection and analysis of electrocardiographic signals offers a means for increased computational speed and the opportunity for design of customized architecture to address real-time requirements. A system using the Motorola 56001 DSP chip has been designed to realize cycle-by-cycle detection (triggering) and waveform analysis using a time-domain template matching technique, correlation waveform analysis (CWA). The system digitally samples an electrocardiographic signal at 1000 Hz, incorporates an adaptive trigger for detection of cardiac events, and classifies each waveform as normal or abnormal. Ten paired sets of single-chamber bipolar intracardiac electrograms (1-500 Hz) were processed with each pair containing a sinus rhythm (SR) passage and a corresponding arrhythmia segment from the same patient. Four of ten paired sets contained intraatrial electrograms that exhibited retrograde atrial conduction during ventricular pacing; the remaining six paired sets of intraventricular electrograms consisted of either ventricular tachycardia (4) or paced ventricular rhythm (2). Of 2,978 depolarizations in the test set, the adaptive trigger failed to detect 6 (99.8% detection sensitivity) and had 11 false triggers (99.6% specificity). Using patient dependent thresholds for CWA to classify waveforms, the program correctly identified 1,175 of 1,197 (98.2% specificity) sinus rhythm depolarizations and 1,771 of 1,781 (99.4% sensitivity) abnormal depolarizations. From the results, the algorithm appears to hold potential for applications such as real-time monitoring of electrophysiology studies or detection and classification of tachycardias in implantable antitachycardia devices.
引用
收藏
页码:1373 / 1379
页数:7
相关论文
共 14 条
[1]  
ARZBAECHER R, 1971, JAAMI Journal of the Association for the Advancement of Medical Instrumentation, V5, P104
[2]  
CHIANG CJ, 1992, 14TH ANN INT C IEEE, P496
[3]   REAL-TIME ARRHYTHMIA IDENTIFICATION FROM AUTOMATED-ANALYSIS OF INTRAATRIAL AND INTRAVENTRICULAR ELECTROGRAMS [J].
CHIANG, CMJ ;
JENKINS, JM ;
DICARLO, LA ;
LIN, DP ;
LI, PC .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (01) :223-227
[4]   IMPLANTABLE CARDIOVERTER DEFIBRILLATOR PROARRHYTHMIA - CASE-REPORT AND REVIEW OF THE LITERATURE [J].
COHEN, TJ ;
CHIEN, WW ;
LURIE, KG ;
LEE, MA ;
LESH, MD ;
SCHEINMAN, MM ;
GRIFFIN, JC .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (09) :1326-1329
[5]   A TIME-DOMAIN ANALYSIS OF INTRACARDIAC ELECTROGRAMS FOR ARRHYTHMIA DETECTION [J].
DICARLO, LA ;
THRONE, RD ;
JENKINS, JM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (02) :329-336
[6]  
FELDMAN CL, 1971, COMPUT BIOMED RES, V4, P666
[7]   AUTOMATED ELECTROCARDIOGRAPHY AND ARRHYTHMIA MONITORING [J].
JENKINS, JM .
PROGRESS IN CARDIOVASCULAR DISEASES, 1983, 25 (05) :367-408
[8]  
KENNEDY JB, 1986, BASIC STATISTICAL ME, P410
[9]  
Lee E. A., 1989, IEEE ASSP Magazine, V6, P4, DOI 10.1109/53.16934
[10]   Programmable DSP architectures. - Part 1 [J].
Lee, Edward A. .
IEEE ASSP magazine, 1988, 5 (04) :4-19