USE OF REFRACTOMETRY TO IDENTIFY OPIOID-CONTAINING SOLUTIONS

被引:6
作者
EAGLE, CJ
MALTBY, JR
KRYSKI, S
HARDY, D
机构
[1] Department of Anaesthesia, Foothills Hospital, University of Calgary, Calgary
来源
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE | 1994年 / 41卷 / 03期
关键词
ANALGESICS; ABUSE ALFENTANIL FENTANYL MORPHINE; SUFENTANIL; MEASUREMENT TECHNIQUES; REFRACTOMETRY;
D O I
10.1007/BF03009840
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
The purpose of this laboratory study was to assess the value of refractometry in identifying the contents of a variety of opioid-containing solutions. A handheld refractometer was used to document the refraction produced by the undiluted contents of alfentanil, fentanyl, morphine, sufentanil ampoules and by solutions of Ringers lactate, 0.9% saline, 3.3% dextrose in 0.3% saline, and distilled water. Each opioid was then serially diluted in serial 1:2, 1:4, and 1:8 dilutions in each of these solutions and the refractions of each determined. Based on this information, blinded identification of various diluted opioid solutions was attempted. Refractometer values for undiluted fentanyl and sufentanil were identical with those for distilled water. Those for undiluted alfentanil and morphine were almost identical with each other and with I:2 and 1:4 dilutions of either drug in Ringer's lactate or 0.9% saline. We conclude that refractometry is an unreliable screening method to detect tampering with opioid solutions.
引用
收藏
页码:248 / 252
页数:5
相关论文
共 9 条
[1]
NARCOTICS CONTROL IN ANESTHESIA TRAINING [J].
ADLER, GR ;
POTTS, FE ;
KIRBY, RR ;
LOPALO, S ;
HILYARD, GR .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1985, 253 (21) :3133-3136
[2]
REFRACTOMETRIC SCREENING OF CONTROLLED SUBSTANCES USED IN OPERATING-ROOMS [J].
BARDAS, SL ;
FERRARESI, VF ;
LIEBERMAN, SF .
AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1992, 49 (11) :2779-2781
[3]
USE OF REFRACTOMETERS TO DETECT CONTROLLED-SUBSTANCE TAMPERING [J].
CHEUNG, JF ;
CHONG, S ;
KITRENOS, JG ;
FUNG, HL .
AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1991, 48 (07) :1488-1492
[4]
REFRACTOMETRIC TESTING OF ALFENTANIL HYDROCHLORIDE, FENTANYL CITRATE, SUFENTANIL CITRATE, AND MIDAZOLAM HYDROCHLORIDE [J].
DONNELLY, AJ ;
NEWMAN, LM ;
PETRYNA, HM ;
IVANKOVICH, AD .
AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1993, 50 (02) :298-300
[5]
FARLEY WJ, 1983, ANESTH ANALG, V62, P465
[6]
REFRACTOMETER SCREENING OF CONTROLLED SUBSTANCES IN AN OPERATING-ROOM SATELLITE PHARMACY [J].
GILL, DL ;
GOODWIN, SR ;
KNUDSEN, AK ;
WADE, C .
AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1990, 47 (04) :817-818
[7]
MALTBY JR, IN PRESS CAN J ANAES
[8]
A RELIABLE ACCOUNTING SYSTEM FOR CONTROLLED SUBSTANCES IN THE OPERATING-ROOM [J].
SCHMIDT, KA ;
SCHLESINGER, MD .
ANESTHESIOLOGY, 1993, 78 (01) :184-190
[9]
OPIOID ADDICTION IN ANESTHESIOLOGY [J].
SILVERSTEIN, JH ;
SILVA, DA ;
IBERTI, TJ .
ANESTHESIOLOGY, 1993, 79 (02) :354-375