CLINICAL USEFULNESS OF THE GLUCOSE-CONCENTRATION IN THE SUBCUTANEOUS TISSUE - PROPERTIES AND PITFALLS OF ELECTROCHEMICAL BIOSENSORS

被引:25
作者
FISCHER, U
REBRIN, K
VONWOEDTKE, T
ABEL, P
机构
关键词
GLUCOSE ELECTRODE; BIOSENSOR; IMPLANTATION; SUBCUTANEOUS TISSUE;
D O I
10.1055/s-2007-1001747
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Biosensors are miniaturized analytical tools which comprise a biological detection element providing specificity to the analyte, and a physical transducer which guarantees an output signal, e.g. an electric current the size of which is proportional to the concentration of the analyte. They provide the unique possibility of continuous in vivo monitoring. Glucosensors were in fact the first biosensors under study. Among them, the most advanced devices are measuring amperometrically the hydrogen peroxide generated in a stoichiometric relation to the prevailing glucose concentration during glucose oxidase-mediated glucose oxidation. They proved useful in commercially available glucose analyzers and in experimental subcutaneous monitoring. Here it is shown (a) that under steady state conditions the s.c. glucose concentration is nearly identical to that in blood, (b) that s.c. inserted glucose electrodes do mirror the intracorporal glucose concentration both under hypo-, normo-, and hyperglycaemic conditions with a clinically relevant accuracy, (c) that even stable feedback control of intracorporal glucose concentration is possible employing s.c. glucosensor signal as an input to automated insulin pump controller, and (d) that stable function of s.c. sensor is usually accomplished over intervals up to one day but in some cases applications over up to ten days could be realized. The underlying problem consists in an insufficient functional biostability which is a function of biocompatibility and size of the sensor, of its sterility, and of the permanent skin penetration. The latter is still required to get the device in place, to keep it in function, and to make use of the data under any condition. At this time, s.c. glucose electrodes to be employed as hypoglycaemia-warning systems over one day are considered clinically important and technically achievable.
引用
收藏
页码:515 / 522
页数:8
相关论文
共 31 条
  • [1] ABEL P, 1984, BIOMED BIOCHIM ACTA, V43, P577
  • [2] ADVANCES IN THE USE OF INVIVO SENSORS
    ALCOCK, SJ
    DANIELSSON, B
    TURNER, APF
    [J]. BIOSENSORS & BIOELECTRONICS, 1992, 7 (04) : 243 - 254
  • [3] APPLICATION OF CHRONIC INTRAVASCULAR BLOOD-GLUCOSE SENSOR IN DOGS
    ARMOUR, JC
    LUCISANO, JY
    MCKEAN, BD
    GOUGH, DA
    [J]. DIABETES, 1990, 39 (12) : 1519 - 1526
  • [4] BIOCOMPATIBILITY CONSIDERATIONS AT STIMULATING ELECTRODE INTERFACES
    BEARD, RB
    HUNG, BN
    SCHMUKLER, R
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1992, 20 (03) : 395 - 410
  • [5] BENDTSON I, 1988, ACTA MED SCAND, V223, P543
  • [6] DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING
    BINDRA, DS
    ZHANG, YN
    WILSON, GS
    STERNBERG, R
    THEVENOT, DR
    MOATTI, D
    REACH, G
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (17) : 1692 - 1696
  • [7] MICRODIALYSIS MEASUREMENT OF THE ABSOLUTE GLUCOSE-CONCENTRATION IN SUBCUTANEOUS ADIPOSE-TISSUE ALLOWING GLUCOSE MONITORING IN DIABETIC-PATIENTS
    BOLINDER, J
    UNGERSTEDT, U
    ARNER, P
    [J]. DIABETOLOGIA, 1992, 35 (12) : 1177 - 1180
  • [8] ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
    CLARK, LC
    LYONS, C
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) : 29 - &
  • [9] EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE
    CLARKE, WL
    COX, D
    GONDERFREDERICK, LA
    CARTER, W
    POHL, SL
    [J]. DIABETES CARE, 1987, 10 (05) : 622 - 628
  • [10] NONINVASIVE OPTICAL POLARIMETRIC GLUCOSE SENSING USING A TRUE PHASE MEASUREMENT TECHNIQUE
    COTE, GL
    FOX, MD
    NORTHROP, RB
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (07) : 752 - 756