THE RANGE OF ALBUMIN CONCENTRATIONS IN THE SINGLE-VOID 1ST MORNING URINE OF 1090 HEALTHY-YOUNG CHILDREN

被引:4
作者
KODAMA, K
TOMIOKA, M
OTANI, T
SHIMIZU, S
UCHIGATA, Y
HIRATA, Y
机构
[1] TOKYO WOMENS MED COLL,CTR DIABET,8-1 KAWADA CHO,SHINJUKU KU,TOKYO 162,JAPAN
[2] TOKYO WOMENS MED COLL,DEPT HYG & PUBL HLTH,SHINJUKU KU,TOKYO 162,JAPAN
关键词
Albumin concentration; Single-void first morning urine; Turbidimetry immunoassay method;
D O I
10.1016/0168-8227(90)90009-I
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To predict microalbuminuria easily in the diabetic outpatient clinic, we determined the range of albumin concentrations in the single-void first morning urine in 1090 healthy subjects of age 6-11 by the modified turbidimetry immunoassay (TIA) method, which uses 96-well microplates and a microplate reader to perform the assay quickly and conveniently. As the correlation coefficient of albumin concentration by the TIA uncorrected for creatinine versus corrected for creatinine was r = 0.79 (P < 0.005), the values uncorrected for creatinine were used. When the distribution of values from 1090 healthy young children was simulated by using the chi-square test (k = 1), the 95% confidence interval was 0-18 μg/ml. © 1990.
引用
收藏
页码:55 / 58
页数:4
相关论文
共 13 条
[1]   1ST MORNING URINARY ALBUMIN CONCENTRATION IS A GOOD PREDICTOR OF 24-HOUR URINARY ALBUMIN EXCRETION IN CHILDREN WITH TYPE-1 (INSULIN-DEPENDENT) DIABETES [J].
COWELL, CT ;
ROGERS, S ;
SILINK, M .
DIABETOLOGIA, 1986, 29 (02) :97-99
[2]   URINARY ALBUMIN EXCRETION IN SCHOOL-CHILDREN [J].
DAVIES, AG ;
POSTLETHWAITE, RJ ;
PRICE, DA ;
BURN, JL ;
HOULTON, CA ;
FIELDING, BA .
ARCHIVES OF DISEASE IN CHILDHOOD, 1984, 59 (07) :625-630
[3]   COMPARISON OF OVERNIGHT, MORNING AND 24-HOUR URINE COLLECTIONS IN THE ASSESSMENT OF DIABETIC MICROALBUMINURIA [J].
ESHOJ, O ;
FELDTRASMUSSEN, B ;
LARSEN, ML ;
MOGENSEN, EF .
DIABETIC MEDICINE, 1987, 4 (06) :531-533
[4]   SCREENING FOR EARLY DIABETIC NEPHROPATHY - WHICH SAMPLE TO DETECT MICROALBUMINURIA [J].
GATLING, W ;
KNIGHT, C ;
HILL, RD .
DIABETIC MEDICINE, 1985, 2 (06) :451-455
[5]   TURBIDIMETRIC MEASUREMENT OF MICROALBUMINURIA [J].
HARMOINEN, A ;
VUORINEN, P ;
JOKELA, H .
CLINICA CHIMICA ACTA, 1987, 166 (01) :85-89
[6]  
KEEN H, 1963, LANCET, V2, P913
[7]   URINARY ALBUMIN MEASUREMENT BY IMMUNOTURBIDIMETRY [J].
LLOYD, DR ;
HINDLE, EJ ;
MARPLES, J ;
GATT, JA .
ANNALS OF CLINICAL BIOCHEMISTRY, 1987, 24 :209-210
[8]  
MOGENSEN CE, 1988, LANCET, V1, P867
[10]  
MOGENSEN CE, 1982, DIABETIC RENAL RETIN, P41