THERMAL RESPONSE OF TNS GRAPHITE LINER AND 1ST WALL MATERIALS

被引:2
作者
BOWERS, DA
机构
[1] McDonnell Douglas Astronautics Company - St. Louis, St. Louis
关键词
D O I
10.1016/0022-3115(79)90492-6
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Operating temperatures of the plasma chamber for the General Atomic Company TNS (The Next Step) fusion reactor are defined in this study. Specifically, the thermal response of protective graphite liners (tiles) and two wall materials are assessed for normal PGFR (Power Generating Fusion Reactor) plasma heat loads. Results indicate that graphite tile temperatures will be acceptable for use on the inboard wall, and that either Inconel or titanium chamber walls exhibit satisfactory temperatures for structurally feasible wall designs. © 1979.
引用
收藏
页码:209 / 213
页数:5
相关论文
共 4 条
[1]  
BADGER B, 1975, UWFDM150 U WISC
[2]  
FIVEL HJ, 1976, COO28024 M DOUGL AST
[3]  
TRACHSEL C, 1979, J NUCL MAT, V85, P165
[4]  
1977, GAC ANL TNS SCOPING, V6