摘要
Using image-directed and color Doppler ultrasonography (ICDUS), we examined 65 patients with single kidney biopsy and diagnosed one arteriovenous fistula (AVF) in each of 8 kidneys. Three of them were associated with pseudoaneurysms. Three of the patients with AVF who presented with macrohematuria underwent angiography. Therapeutic percutaneous embolization was performed in 2 of them. The remaining 6 patients were followed up with ICDUS. All the lesions had disappeared at the end of a 6-month period. We conclude that ICDUS is an easy and noninvasive imaging technique in the diagnosis of postbiopsy native renal AVFs. (C) 1995 John Wiley & Sons, Inc.
引用
收藏
页码:239 / 242
页数:4
相关论文
共 12 条
[1]  
Renowden SA, Cochlin DLI, The potential use of diuresis Doppler sonography in PUJ obstruction, Clin Radiol, 46, (1992)
[2]  
Ozbek SS, Aytac SK, Erden MI, Et al., Intrarenal Doppler findings of upstream renal artery stenosis: a preliminary report, Ultrasound Med Biol, 19, (1993)
[3]  
Middleton WD, Kellman GM, Melson GL, Et al., Postbiopsy renal transplant arteriovenous fistulas: color Doppler US characteristics, Radiology, 171, (1989)
[4]  
Deane C, Cowan N, Giles J, Et al., Arteriovenous fistulas in renal transplants: color Doppler ultrasound observations, Urol Radiol, 13, (1992)
[5]  
Baquero A, Morris MC, Cope C, Et al., Selective embolization of vascular complications following renal biopsy of the transplant kidney, Transplant Proc, 27, (1985)
[6]  
Wickre CG, Golper TA, Complications of percutaneous needle biopsy of the kidney, Am J Nephrol, 2, (1982)
[7]  
Norris CS, Barnes RW, Renal artery flow velocity analysis: a sensitive measure of experimental and clinical neovascular resistance, J Surg Res, 36, (1984)
[8]  
Renowden SA, Blethyn J, Cochlin DLI, Duplex and colour flow sonography in the diagnosis of postbiopsy arteriovenous fistulae in the transplant kidney, Clin Radiol, 45, (1992)
[9]  
Derchi LE, Martinoli C, Pontremoli R, Et al., Postbiopsy arteriovenous fistulas of the native kidneys diagnosed by Doppler US, Eur Radiol, 3, (1993)
[10]  
Derchi LE, Saffioti S, De Caro G, Et al., Arteriovenous fistula of the native kidney: diagnosis by duplex Doppler ultrasound, J Ultrasound Med, 10, (1991)