REMARKABLY SELECTIVE METALLIZED-CARBON AMPEROMETRIC BIOSENSORS

被引:41
作者
WANG, J [1 ]
LU, F [1 ]
ANGNES, L [1 ]
LIU, J [1 ]
SAKSLUND, H [1 ]
CHEN, Q [1 ]
PEDRERO, M [1 ]
CHEN, L [1 ]
HAMMERICH, O [1 ]
机构
[1] UNIV COPENHAGEN,HC ORSTED INST,DEPT CHEM,DK-2100 COPENHAGEN,DENMARK
关键词
AMPEROMETRY; BIOSENSORS; METALLIZED CARBONS; ELECTROCATALYSIS; GLUCOSE; SELECTIVITY;
D O I
10.1016/0003-2670(94)00341-I
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of metallized carbon transducers results in remarkably selective amperometric biosensors. Such focus on the transducer eliminates major electroactive interferences in the first place, and hence circumvents the need for anti-interference layers. The remarkable selectivity of metal-dispersed carbons is attributed to their strong, preferential, electrocatalytic action towards the detection of the enzymatically-liberated hydrogen peroxide and reduced nicotinamide cofactor (NADH). Such activity allows tuning of the operating potential to the region (+0.1 to -0.2 V) where unwanted reactions do not occur. This article reviews the development of metallized-carbon biosensors, with particular emphasis on metallized carbon-paste enzyme electrodes, miniaturized devices based on electrochemical deposition of the metal/enzyme layer and metal-dispersed sensor strips.
引用
收藏
页码:3 / 7
页数:5
相关论文
共 42 条
[1]   MASS-PRODUCTION OF BIOSENSORS [J].
ALVAREZICAZA, M ;
BILITEWSKI, U .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :A525-A533
[2]   LONG-TERM OPERATIONAL STABILITY OF A MIXED GLUCOSE OXIDASE-REDOX MEDIATOR-CARBON PASTE ELECTRODE [J].
AMINE, A ;
KAUFFMANN, JM ;
PATRIARCHE, GJ ;
KAIFER, AE .
ANALYTICAL LETTERS, 1991, 24 (08) :1293-1315
[3]  
[Anonymous], UNPUB
[4]   SCREEN PRINTED GLUCOSE ELECTRODES BASED ON PLATINIZED CARBON PARTICLES AND GLUCOSE-OXIDASE [J].
CARDOSI, MF ;
BIRCH, SW .
ANALYTICA CHIMICA ACTA, 1993, 276 (01) :69-74
[5]  
Cass A.E.G., 1990, BIOSENSORS PRACTICAL
[6]   FLOW-INJECTION ANALYSIS OF GLUCOSE AT AN AMPEROMETRIC GLUCOSE SENSOR-BASED ON ELECTROCHEMICAL CODEPOSITION OF PALLADIUM AND GLUCOSE-OXIDASE ON A GLASSY-CARBON ELECTRODE [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1993, 278 (01) :17-23
[7]   PLASTICIZED POLY(VINYL CHLORIDE) AS A PERMSELECTIVE BARRIER MEMBRANE FOR HIGH-SELECTIVITY AMPEROMETRIC SENSORS AND BIOSENSORS [J].
CHRISTIE, IM ;
TRELOAR, PH ;
VADGAMA, P .
ANALYTICA CHIMICA ACTA, 1992, 269 (01) :65-73
[8]   MICROBAND ELECTRODES FABRICATED BY SCREEN PRINTING PROCESSES - APPLICATIONS IN ELECTROANALYSIS [J].
CRASTON, DH ;
JONES, CP ;
WILLIAMS, DE ;
ELMURR, N .
TALANTA, 1991, 38 (01) :17-26
[9]   ELECTRICAL COMMUNICATION BETWEEN REDOX CENTERS OF GLUCOSE-OXIDASE AND ELECTRODES VIA ELECTROSTATICALLY AND COVALENTLY BOUND REDOX POLYMERS [J].
DEGANI, Y ;
HELLER, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (06) :2357-2358
[10]   ELECTROCHEMICAL BIOSENSORS [J].
FREW, JE ;
HILL, HAO .
ANALYTICAL CHEMISTRY, 1987, 59 (15) :A933-&