DETERMINATION OF CIRCULATING BLOOD-VOLUME BY MEASUREMENT OF INDOCYANINE GREEN-DYE IN HEMOLYSATE - A PRELIMINARY-STUDY

被引:24
作者
BUSSE, MW
ZISOWSKY, S
HENSCHEN, S
PANNING, B
REILMANN, L
机构
[1] MED SCH HANOVER,DEPT ANAESTHESIOL,W-3000 HANOVER,GERMANY
[2] MED SCH HANOVER,DEPT RADIOL,W-3000 HANOVER,GERMANY
关键词
D O I
10.1016/0024-3205(90)90133-C
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
In 8 emergency care patients blood volume was determined using Cr51 labelled erythrocytes and indocyanine green (ICG). Prior to measurement of ICG in blood with a spectrophotometer, the blood was hemolyzed with Triton-X. A close correlation of r=0.97 between the Cr51 and the ICGTR-X estimates was found; the ICGTR-X volume was about 3% lower than the Cr51 volume. In five additional in vitro experiments the ICGTR-X method was found to reflect real volumes with an insignificant error of less than 1%. Blood volume determination with ICGTR-X cannot be applied in cases of circulatory failure. ICG should be administered in a dose of 0.5 mg/kg of body weight. For calibration purposes, a two point calibration curve (point 1: point of intersection of x and y axis; point 2: 5 mg ICG/1 of blood) is sufficient. From these preliminary experiments it is concluded that the ICGTR-X method is a rapid and simple technique of blood volume determination with multiple reproducibility which can be carried out in any clinical laboratory. © 1990.
引用
收藏
页码:647 / 652
页数:6
相关论文
共 8 条
[1]  
BOENING D, 1983, Journal of Applied Physiology Respiratory Environmental and Exercise Physiology, V54, P118
[2]   DETERMINATION OF BLOOD VOLUME USING INDOCYANINE GREEN (CARDIO-GREENR) DYE [J].
BRADLEY, EC ;
BARR, JW .
LIFE SCIENCES PART 1 PHYSIOLOGY AND PHARMACOLOGY AND PART 2 BIOCHEMISTRY GENERAL AND MOLECULAR BIOLOGY, 1968, 7 (17P1) :1001-&
[3]   INDOCYANINE GREEN - OBSERVATIONS ON ITS PHYSICAL PROPERTIES, PLASMA DECAY, AND HEPATIC EXTRACTION [J].
CHERRICK, GR ;
STEIN, SW ;
LEEVY, CM ;
DAVIDSON, CS .
JOURNAL OF CLINICAL INVESTIGATION, 1960, 39 (04) :592-600
[4]   A METHOD FOR MEASUREMENT OF TOTAL CIRCULATING BLOOD-VOLUME USING INDOCYANINE GREEN [J].
HANEDA, K ;
HORIUCHI, T .
TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1986, 148 (01) :49-56
[5]   PERIPHERAL VS CENTRAL CIRCULATION TIMES DURING CPR - A PILOT-STUDY [J].
KUHN, GJ ;
WHITE, BC ;
SWETNAM, RE ;
MUMEY, JF ;
RYDESKY, MF ;
TINTINALLI, JE ;
KROME, RL ;
HOEHNER, PJ .
ANNALS OF EMERGENCY MEDICINE, 1981, 10 (08) :417-419
[6]  
LEWIS FR, 1982, ANN NY ACAD SCI, V384, P393
[7]  
SOKOLOW M, 1985, KARDIOLOGIYA, P70
[8]  
SOLOMON N, 1963, BLOOD VOLUME, P147