EFFECTS OF IRRADIANCE AND SPOT SIZE ON PULSED HOLMIUM LASER ABLATION OF TISSUE

被引:6
作者
DOMANKEVITZ, Y [1 ]
LEE, MS [1 ]
NISHIOKA, NS [1 ]
机构
[1] HARVARD UNIV, SCH MED, DEPT MED, MED SERV, GASTROINTESTINAL UNIT, BOSTON, MA 02115 USA
来源
APPLIED OPTICS | 1993年 / 32卷 / 04期
关键词
D O I
10.1364/AO.32.000569
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Threshold radiant exposures for pulsed holmium laser ablation of tissue were measured with a high-speed framing camera. The effects of laser irradiance and beam size on ablation threshold were investigated. Threshold radiant exposure decreased with increasing laser irradiance over the range of 10(5)-10(7) W/cm2. Over the range of spot sizes examined (243-970 mum) an increase in the laser beam diameter reduced the laser irradiance required for ablation. At larger spot sizes the ablation event was occasionally initiated from multiple sites. These results suggest that the rate of energy deposition and laser-beam geometry affect the events preceding the onset of ablation and should be considered when pulsed laser ablation of tissue is modeled or quantified.
引用
收藏
页码:569 / 573
页数:5
相关论文
共 9 条
[1]   SELECTIVE PHOTOTHERMOLYSIS - PRECISE MICROSURGERY BY SELECTIVE ABSORPTION OF PULSED RADIATION [J].
ANDERSON, RR ;
PARRISH, JA .
SCIENCE, 1983, 220 (4596) :524-527
[2]   THE OPTICS OF HUMAN-SKIN [J].
ANDERSON, RR ;
PARRISH, JA .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1981, 77 (01) :13-19
[3]   MEASUREMENT OF LASER ABLATION THRESHOLD WITH A HIGH-SPEED FRAMING CAMERA [J].
DOMANKEVITZ, Y ;
NISHIOKA, NS .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1990, 26 (12) :2276-2278
[4]   DIFFERENT LASERS FOR ANGIOPLASTY - THERMOOPTIC COMPARISON [J].
FURZIKOV, NP .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1987, 23 (10) :1751-1755
[5]   A MODEL FOR THERMAL ABLATION OF BIOLOGICAL TISSUE USING LASER-RADIATION [J].
PARTOVI, F ;
IZATT, JA ;
COTHREN, RM ;
KITTRELL, C ;
THOMAS, JE ;
STRIKWERDA, S ;
KRAMER, JR ;
FELD, MS .
LASERS IN SURGERY AND MEDICINE, 1987, 7 (02) :141-154
[6]  
PRAHL S, 1991, COMMUNICATION
[7]  
PRINCE M, 1988, THESIS MIT CAMBRIDGE
[8]  
SPERLING LH, 1986, INTRO PHYSICAL POLYM
[9]   PULSED CO2-LASER TISSUE ABLATION - MEASUREMENT OF THE ABLATION RATE [J].
WALSH, JT ;
DEUTSCH, TF .