CLINICAL NERVE RECONSTRUCTION WITH A BIOABSORBABLE POLYGLYCOLIC ACID TUBE

被引:425
作者
MACKINNON, SE
DELLON, AL
机构
[1] UNIV TORONTO, SUNNYBROOK MED CTR, DEPT PLAST SURG, TORONTO M4N 3M5, ONTARIO, CANADA
[2] JOHNS HOPKINS UNIV, SCH MED, DEPT PLAST SURG & NEUROL SURG, BALTIMORE, MD 21205 USA
关键词
D O I
10.1097/00006534-199003000-00015
中图分类号
R61 [外科手术学];
学科分类号
摘要
Microneurosurgical techniques to reconstruct nerve gaps with nerve grafts frequently fail to achieve excellent functional results and create donor-site morbidity. In the present study, 15 patients had gaps of 0.5 to 3.0 cm (mean 1.7 cm) in digital nerves reconstructed by one surgeon with a bioabsorbable polyglycolic acid (PGA) tube. A final evaluation of sensibility was done by a second surgeon at a mean postoperative interval of 22.4 months (range 11 to 32 months). These were all secondary reconstructions. The evaluation included a digital nerve block with local anesthetic for the intact (not reconstructed) digital nerve. Excellent functional sensation (moving two-point discrimination less than or equal to 3 mm and/or static two-point discrimination less than or equal to 6 mm) was present in 33 percent and good functional sensation (moving two-point discrimination of 4 to 7 mm and/or static two-point discrimination of 7 to 15 mm) in 53 percent of the digital nerve reconstructions. One patient with poor sensory recovery and one with no recovery were judged as functional failures (14 percent). Absence of pain at the site of reconstruction was judged by the patient to be excellent in 40 percent, good in 33 percent, and poor in 27 percent. We conclude that reconstruction of nerve gaps of up to 3.0 cm with a bioabsorbable PGA tube gives clinical results at least comparable to the classic nerve graft technique while avoiding donor-site morbidity. © 1990 American Society of Plastic Surgeons.
引用
收藏
页码:419 / 424
页数:6
相关论文
共 40 条
  • [1] BEAZLEY WC, 1984, CLIN ORTHOP RELAT R, P208
  • [2] SELECTIVE REINNERVATION OF DISTAL MOTOR STUMPS BY PERIPHERAL MOTOR AXONS
    BRUSHART, TME
    SEILER, WA
    [J]. EXPERIMENTAL NEUROLOGY, 1987, 97 (02) : 289 - 300
  • [3] CHIU DTW, 1982, SURGERY, V91, P226
  • [4] CHIU DTW, 1987, MAY PLAST SURG RES C
  • [5] NERVE REGENERATION THROUGH COLLAGEN TUBES
    COLIN, W
    DONOFF, RB
    [J]. JOURNAL OF DENTAL RESEARCH, 1984, 63 (07) : 987 - 993
  • [6] Dellon A L, 1978, J Hand Surg Am, V3, P474
  • [7] DELLON AL, 1983, J HAND SURG-AM, V8, P865
  • [8] RELIABILITY OF 2-POINT DISCRIMINATION MEASUREMENTS
    DELLON, AL
    MACKINNON, SE
    CROSBY, PM
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1987, 12A (05): : 693 - 696
  • [9] AN ALTERNATIVE TO THE CLASSICAL NERVE GRAFT FOR THE MANAGEMENT OF THE SHORT NERVE GAP
    DELLON, AL
    MACKINNON, SE
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1988, 82 (05) : 849 - 856
  • [10] DELLON AL, 1981, EVALUATION SENSIBILI, P203