REFINEMENT AND EVALUATION OF AN AUTOMATED MASS-SPECTROMETER FOR NITROGEN ISOTOPE ANALYSIS BY THE RITTENBERG TECHNIQUE

被引:34
作者
MULVANEY, RL
LIU, YP
机构
[1] Department of Agronomy, University of Illinois, Urbana, Illinois 61801, Turner Hall
来源
JOURNAL OF AUTOMATIC CHEMISTRY | 1991年 / 13卷 / 06期
关键词
D O I
10.1155/S1463924691000433
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An apparatus designed to automatically perform hypobromite oxidations of ammonium salt samples for nitrogen isotope analyses with a mass spectrometer was modified to improve performance and reduce analysis time. As modified, reference N2 is admitted to the mass spectrometer between samples from a dedicated inlet manifold, for calibration at the same pressure as that of the preceding sample. Analyses can be performed on samples containing 10-mu-g to 1 mg of N (or more), at a rate of up to 350 samples/day. When operated with a double-collector mass spectrometer, the standard deviation at the natural abundance level (10 analyses, 50-150-mu-g N) was < 0.0001 atom % N-15. Very little memory was observed when natural abundance samples (0.366 atom % N-15) were analysed following samples containing 40 atom % N-15. Analyses in the range, 0.2 to 1 atom % N-15 (50-150-mu-g N), were in good agreement with manual Rittenberg analyses (1 mg N) using a dual-inlet system, and precision was comparable. For enrichments of 2 to 20 atom % N-15, automated analyses were slightly lower than manual analyses, which was attributed to outgassing of N2 from the plastic microplate used to contain samples.
引用
收藏
页码:273 / 280
页数:8
相关论文
共 10 条
[1]  
BARRIE A, 1984, SPECTROSC-INT J, V3, P439
[2]  
Bremner J. M., 1982, Methods of soil analysis. Part 2. Chemical and microbiological properties, P595
[3]  
Buresh R. J., 1982, Fertilizer Research, V3, P37, DOI 10.1007/BF01063408
[4]  
GILKEY HT, 1991, HEATING PIPING AIR C, V63, P41
[5]   AUTOMATION OF AN INTERFACE BETWEEN A NITROGEN ANALYZER AND AN ISOTOPE RATIO MASS-SPECTROMETER [J].
MARSHALL, RB ;
WHITEWAY, JN .
ANALYST, 1985, 110 (07) :867-871
[6]  
MCINTEER BB, 1984, SPECTROSC INT J, V3, P226
[7]  
MCINTEER BB, 1981, RECENT DEV MASS SPEC, P343
[8]   A COMMERCIAL SYSTEM FOR AUTOMATED NITROGEN ISOTOPE-RATIO ANALYSIS BY THE RITTENBERG TECHNIQUE [J].
MULVANEY, RL ;
FOHRINGER, CL ;
BOJAN, VJ ;
MICHLIK, MM ;
HERZOG, LF .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (02) :897-903
[9]   SIMULTANEOUS MEASUREMENTS AND DETERMINATIONS OF STABLE CARBON AND NITROGEN ISOTOPE RATIOS, AND ORGANIC-CARBON AND NITROGEN CONTENTS IN BIOLOGICAL SAMPLES BY COUPLING OF A SMALL QUADRUPOLE MASS-SPECTROMETER AND MODIFIED CARBON-NITROGEN ELEMENTAL ANALYZER [J].
OTSUKI, A ;
INO, Y ;
FUJII, T .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 48 (FEB) :343-346
[10]   INTERFACING AN AUTOMATIC ELEMENTAL ANALYZER WITH AN ISOTOPE RATIO MASS-SPECTROMETER - THE POTENTIAL FOR FULLY AUTOMATED TOTAL NITROGEN AND N-15 ANALYSIS [J].
PRESTON, T ;
OWENS, NJP .
ANALYST, 1983, 108 (1289) :971-977