EXPERIMENTAL AND ANALYTICAL INVESTIGATION OF A CAPILLARY PUMPED LOOP

被引:51
作者
DICKEY, JT
PETERSON, GP
机构
[1] Department of Mechanical Engineering, Texas A&M University, College Station, 77843, TX
关键词
Heat pipes;
D O I
10.2514/3.584
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental investigation was conducted on a relatively new and unique type of capillary pumped loop (CPL) at various power inputs and adverse tilts in order to verify the operational parameters and measure the performance limits. A concurrently developed computer model was compared with the experimental data to determine the accuracy of the model and verify the predicted trends. The model shows good agreement with the experimental data and indicates that the overall transport capacity of this design is significantly greater than what would normally be expected in conventional heat pipes. The steady-state temperature variations are presented as a function of input power and adverse tilt, along with the transient response characteristics of the CPL. Also, a comparison is made between data obtained by the authors and that supplied by the manufacturer.
引用
收藏
页码:602 / 607
页数:6
相关论文
共 10 条
[1]
CHAPMAN A, 1987, FUNDAMENTALS HEAT TR, P98
[2]
Dunn P., 2016, HEAT PIPES
[3]
Kaviany M., 1995, PRINCIPLES HEAT TRAN, V2nd ed
[4]
Kays W. M., 1993, CONVECTIVE HEAT MASS, P138
[5]
KU J, 1992, 27TH P AIAA THERM C
[6]
LAUB JH, 1961, CALTECH TR32196 JET
[7]
MAIDANIK Y, 1991, ESA SP324
[8]
Maidanik Y., 1985, US patent, Patent No. 4515209
[9]
MCGINNESS HD, 1961, CALTECH RS3610 JET P, V1, P9
[10]
STENGER FJ, 1966, NASA TM X1310