ORIGIN OF ARTERIAL-WALL DISSECTIONS INDUCED BY PULSED EXCIMER AND MIDINFRARED LASER ABLATION IN THE PIG

被引:104
作者
VANLEEUWEN, TG
VANERVEN, L
MEERTENS, JH
MOTAMEDI, M
POST, MJ
BORST, C
机构
[1] INTERUNIV CARDIOL INST NETHERLANDS,UTRECHT,NETHERLANDS
[2] UNIV TEXAS,MED BRANCH,GALVESTON,TX 77550
关键词
D O I
10.1016/0735-1097(92)90627-Y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To study adjacent tissue damage after delivery of holmium, thulium and excimer laser pulses, porcine thoracic aortas were irradiated in vivo. After 3 days, microscopic analysis of 67 craters produced by all three lasers demonstrated large dissections extending from the craters. The mean diameter of the dissections was smaller for excimer-induced craters (1.38 +/- 0.42 mm; n = 22) than for holmium-induced (2.7 +/- 0.87 mm; n = 22) and thulium-induced (2.37 +/- 0.42 mm; n = 14) craters (p < 0.01 vs. mid-infrared dissections). In addition, microscopic analysis demonstrated necrosis adjacent to the crater. The lateral necrotic zones of the thulium-induced craters were smaller than the holmium- and excimer-induced necrotic zones (p < 0.01). To identify the origin of the excessive tissue tearing, laser-saline and laser-tissue interaction were compared in vitro by time-resolved flash photography. In saline solution, the mid-infrared lasers showed bubble formation on a microsecond time scale. The excimer laser produced similar bubbles in the vicinity of tissue. For all three lasers, elevation of the tissue surface was shown during in vitro ablation. Dimension (diameter up to 4 mm) and time course (rise time of 100 to 300-mu-s) of bubble formation and tissue elevation were strikingly similar. Thus, tissue dissections are caused by the expansion of a vapor bubble within the target tissue. Coronary dissections after excimer and mid-infrared laser angioplasty might be related to the forceful bubble expansion.
引用
收藏
页码:1610 / 1618
页数:9
相关论文
共 26 条
[1]  
BONNER RF, 1990, LASERS CARDIOVASCULA, P31
[2]   NEW MECHANISM OF CAVITATION DAMAGE [J].
CHEN, YL ;
ISRAELACHVILI, J .
SCIENCE, 1991, 252 (5009) :1157-1160
[3]   GAS CHROMATOGRAPHIC-LIGHT MICROSCOPIC CORRELATIVE ANALYSIS OF EXCIMER LASER PHOTOABLATION OF CARDIOVASCULAR TISSUES - EVIDENCE FOR A THERMAL MECHANISM [J].
CLARKE, RH ;
ISNER, JM ;
DONALDSON, RF ;
JONES, G .
CIRCULATION RESEARCH, 1987, 60 (03) :429-437
[4]   PERCUTANEOUS CORONARY ANGIOPLASTY WITH MIDINFRARED LASER AND A NEW MULTIFIBER CATHETER [J].
GESCHWIND, HJ ;
DUBOISRANDE, JL ;
MURPHYCHUTORIAN, D ;
TOMARU, T ;
ZELINSKY, R ;
LOISANCE, D .
LANCET, 1990, 336 (8709) :245-246
[5]  
GESCHWIND HJ, 1991, MEDTECH, V2, P9
[6]  
GIJSBERS GHM, 1990, J INTERV CARDIOL, V3, P231
[7]  
GIJSBERS GHM, 1991, LASERS SURG MED S, V3, P15
[8]   LASER ABLATION OF HUMAN ATHEROSCLEROTIC PLAQUE WITHOUT ADJACENT TISSUE-INJURY [J].
GRUNDFEST, WS ;
LITVACK, F ;
FORRESTER, JS ;
GOLDENBERG, T ;
SWAN, HJC ;
MORGENSTERN, L ;
FISHBEIN, M ;
MCDERMID, IS ;
RIDER, DM ;
PACALA, TJ ;
LAUDENSLAGER, JB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (04) :929-933
[9]   MECHANISM OF LASER ABLATION IN AN ABSORBING FLUID FIELD [J].
ISNER, JM ;
DEJESUS, SR ;
CLARKE, RH ;
GAL, D ;
RONGIONE, AJ ;
DONALDSON, RF .
LASERS IN SURGERY AND MEDICINE, 1988, 8 (06) :543-554
[10]  
ISNER JM, 1991, LASERS SURG MED S, V3, P63