THE LENS OPACITIES CLASSIFICATION SYSTEM-III

被引:2335
作者
CHYLACK, LT
WOLFE, JK
SINGER, DM
LESKE, MC
BULLIMORE, MA
BAILEY, IL
FRIEND, J
MCCARTHY, D
WU, SY
机构
[1] HARVARD UNIV,SCH MED,BOSTON,MA 02115
[2] SUNY,DEPT PREVENT MED,STONY BROOK,NY 11794
[3] UNIV CALIF BERKELEY,SCH OPTOMETRY,BERKELEY,CA 94720
关键词
D O I
10.1001/archopht.1993.01090060119035
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective.-To develop the Lens Opacities Classification System III (LOCS III) to overcome the limitations inherent in lens classification using LOCS II. These limitations include unequal intervals between standards, only one standard for color grading, use of integer grading, and wide 95% tolerance limits. Design and Results.-The LOCS III contains an expanded set of standards that were selected from the Longitudinal Study of Cataract slide library at the Center for Clinical Cataract Research, Boston, Mass. It consists of six slit-lamp images for grading nuclear color (NC) and nuclear opalescence (NO), five retroillumination images for grading cortical cataract (C), and five retroillumination images for grading posterior subcapsular (P) cataract. Cataract severity is graded on a decimal scale, and the standards have regularly spaced intervals on a decimal scale. The 95% tolerance limits are reduced from 2.0 for each class with LOCS II to 0.7 for nuclear opalescence, 0.7 for nuclear color, 0.5 for cortical cataract, and 1.0 for posterior subcapsular cataract with the LOCS III, with excellent interobserver agreement. Conclusion.-The LOCS III is an improved LOCS system for grading slit-lamp and retroillumination images of age-related cataract.
引用
收藏
页码:831 / 836
页数:6
相关论文
共 33 条
[1]   A NEW METHOD FOR DOCUMENTING LENS OPACITIES [J].
ADAMSONS, I ;
TAYLOR, KI ;
ENGER, C ;
TAYLOR, HR .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1991, 111 (01) :65-70
[2]  
AGOSTON GA, 1987, COLOR TEORY ITS APPL, P53
[3]  
BAILEY IL, 1991, INVEST OPHTH VIS SCI, V32, P422
[4]  
CHYLACK L T JR, 1990, Investigative Ophthalmology and Visual Science, V31, P374
[5]   LENS OPACITIES CLASSIFICATION SYSTEM-II (LOCS-II) [J].
CHYLACK, LT ;
LESKE, MC ;
MCCARTHY, D ;
KHU, P ;
KASHIWAGI, T ;
SPERDUTO, R .
ARCHIVES OF OPHTHALMOLOGY, 1989, 107 (07) :991-997
[6]   LOSS OF CONTRAST SENSITIVITY IN DIABETIC-PATIENTS WITH LOCS-II CLASSIFIED CATARACTS [J].
CHYLACK, LT ;
PADHYE, N ;
KHU, PM ;
WEHNER, C ;
WOLFE, J ;
MCCARTHY, D ;
ROSNER, B ;
FRIEND, J .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1993, 77 (01) :7-11
[7]   SOURCES OF VARIANCE IN THE OBJECTIVE DOCUMENTATION OF HUMAN CATARACTOUS CHANGE WITH TOPCON SL-45 AND NEITZ-CTR RETROILLUMINATION PHOTOGRAPHY AND COMPUTERIZED IMAGE-ANALYSIS [J].
CHYLACK, LT ;
ROSNER, B ;
CHENG, HM ;
MCCARTHY, D ;
PENNETT, M .
CURRENT EYE RESEARCH, 1987, 6 (12) :1381-1390
[8]  
CHYLACK LT, IN PRESS OPTOM VIS
[9]  
CHYLACK LT, IN PRESS J CATARACT
[10]  
CHYLACK LT, 1991, 6TH ANN COOP CAT RES