DETERMINING PORE-SIZE DISTRIBUTIONS OF ULTRAFILTRATION MEMBRANES BY SOLUTE SIEVING - MATHEMATICAL LIMITATIONS

被引:22
作者
LEYPOLDT, JK
机构
[1] UNIV CALIF SAN DIEGO,DEPT APPL MECH & ENGN SCI,LA JOLLA,CA 92093
[2] UNIV CALIF SAN DIEGO,DEPT MED,LA JOLLA,CA 92093
关键词
MATHEMATICAL TECHNIQUES - Least Squares Approximations - ULTRAFILTRATION - Equipment;
D O I
10.1016/S0376-7388(00)82234-6
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The mathematical problem that results when the pore size distribution of an ultrafiltration membrane is calculated from the dependence of solute sieving coefficient on molecular size is studied. The problem is shown to be mathematically ill-posed and extremely difficult to solve. Using three diffferent solution techniques, it is shown that the exact membrane pore size distribution cannot be uniquely determined from the dependence of sieving coefficient on molecular size. However, one of the proposed solution techniques resolves the pore size distribution into a three-pore equivalent. The resulting three-pore equivalent distribution is useful for estimating the mean, variance and skewness of the membrane pore size distribution.
引用
收藏
页码:289 / 305
页数:17
相关论文
共 33 条
[1]   RESTRICTED TRANSPORT IN SMALL PORES - MODEL FOR STERIC EXCLUSION AND HINDERED PARTICLE MOTION [J].
ANDERSON, JL ;
QUINN, JA .
BIOPHYSICAL JOURNAL, 1974, 14 (02) :130-150
[2]   ULTRAFILTRATION MEMBRANES - CHARACTERIZATION METHODS [J].
CAPANNELLI, G ;
VIGO, F ;
MUNARI, S .
JOURNAL OF MEMBRANE SCIENCE, 1983, 15 (03) :289-313
[3]   INTERFACIAL FORCES, AVERAGE PORE-SIZE, AND PORE-SIZE DISTRIBUTION OF ULTRAFILTRATION MEMBRANES [J].
CHAN, K ;
MATSUURA, T ;
SOURIRAJAN, S .
INDUSTRIAL & ENGINEERING CHEMISTRY PRODUCT RESEARCH AND DEVELOPMENT, 1982, 21 (04) :605-612
[4]   CHARACTERIZATION OF ULTRAFILTRATION MEMBRANES BY POLYMER TRANSPORT MEASUREMENTS [J].
COOPER, AR ;
VANDERVEER, DS .
SEPARATION SCIENCE AND TECHNOLOGY, 1979, 14 (06) :551-556
[5]  
CRONE C, 1984, HDB PHYSL 2, V4, pCH10
[6]  
Curry F.E., 1984, HDB PHYSL CARDIOVASC, VIV
[7]   HETEROPOROUS MODEL OF GLOMERULAR SIZE SELECTIVITY - APPLICATION TO NORMAL AND NEPHROTIC HUMANS [J].
DEEN, WM ;
BRIDGES, CR ;
BRENNER, BM ;
MYERS, BD .
AMERICAN JOURNAL OF PHYSIOLOGY, 1985, 249 (03) :F374-F389
[8]  
DELVES LM, 1985, COMPUTATIONAL METHOD, pCH12
[9]   PERMEABILITY OF ARTIFICIAL MEMBRANES TO A PLURIDISPERSE SOLUTION OF POLYVINYLPYRROLIDONE-I-125 [J].
DUBOIS, R ;
STOUPEL, E .
BIOPHYSICAL JOURNAL, 1976, 16 (12) :1427-1445
[10]  
Forsythe GE., 1977, COMPUTER METHODS MAT