CRT COLORIMETRY .2. METROLOGY

被引:79
作者
BERNS, RS
GORZYNSKI, ME
MOTTA, RJ
机构
[1] Munsell Color Science Laboratory, Center for Imaging Science, Rochester Institute of Technology, Rochester, New York, 14623-5604
[2] Hewlett Packard Company, Vancouver Division, Camas, Washington, 98007
[3] Hewlett Packard Laboratories, Palo Alto, California, 94303
关键词
D O I
10.1002/col.5080180505
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The colorimetric characterization of computer-controlled CRT displays require radiometric measurements with high precision and accuracy in order to achieve acceptable colorimetric accuracy in defining stimuli generated with this type of imaging modality. Precision and accuracy requirements for photometers, colorimeters, and spectroradiometers were evaluated. When models are used to relate digital counts defining a stimulus and resulting spectral radiant exitance, displays are assumed to exhibit channel and spatial independence. A variety of tests and the results of evaluating four imaging systems are described. From these analyses, measurement accuracy is mainly limited by wavelength scale in the case of spectroradiometers and filter fit in the case of colorimeters. Measurement precision is limited by the number of significant figures for fixed-range devices and signal-to-noise limitations for low-luminance stimuli. Display accuracy is limited by a lack of channel and spatial independence. Display precision is mainly limited by the electronic design of the display and the stability and load independence of the gun amplifiers. (C) 1993 John Wiley & Sons, Inc.
引用
收藏
页码:315 / 325
页数:11
相关论文
共 15 条
[1]   COLOR TOLERANCE FEASIBILITY STUDY COMPARING CRT-GENERATED STIMULI WITH AN ACRYLIC-LACQUER COATING [J].
BERNS, RS .
COLOR RESEARCH AND APPLICATION, 1991, 16 (04) :232-242
[2]   CRT COLORIMETRY .1. THEORY AND PRACTICE [J].
BERNS, RS ;
MOTTA, RJ ;
GORZYNSKI, ME .
COLOR RESEARCH AND APPLICATION, 1993, 18 (05) :299-314
[3]   CALIBRATION OF A COMPUTER-CONTROLLED COLOR MONITOR [J].
BRAINARD, DH .
COLOR RESEARCH AND APPLICATION, 1989, 14 (01) :23-34
[4]  
ERB W, 1984, COLOR RES APPL, V9, P84, DOI 10.1002/col.5080090205
[5]  
GORZYNSKI ME, 1989, LMT C1200 NUMS COL S
[6]  
GREENFIELD A, 1988, COMMUNICATION
[7]   MEASUREMENTS OF WHITE UNIFORMITY OF COLOR PICTURE TUBES [J].
KINAMERI, K ;
NONAKA, M .
APPLIED OPTICS, 1974, 13 (06) :1270-1272
[8]  
MOTTA RJ, 1984, THESIS ROCHESTER I T
[9]  
STOKES M, 1992, COMPARISON COLOUR IM, V2, P757
[10]  
1992, ASTM E144592 AM SOC