BEHAVIOR OF TITANIUM AND TITANIA-BASED CERAMICS INVITRO AND INVIVO

被引:66
作者
LI, JG [1 ]
机构
[1] KAROLINSKA INST, CTR DENT TECHNOL & BIOMAT, S-14104 HUDDINGE, SWEDEN
关键词
TITANIUM; TITANIA; BIOCOMPATIBILITY; STABILITY;
D O I
10.1016/0142-9612(93)90028-Z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cylinders, 2.8 mm in diameter and 6 mm in length which were produced from hot isostatically pressed titania (TI), titania-hydroxyapatite composite (TI/HA) and hydroxyapatite (HA) as well as commercially pure titanium (c.p. Ti), were implanted in the femurs of New Zealand white rabbits. The animals were killed at 1 and 3 months after implantation to study the development of bonding strength between the bone and the implant using the push-out test. The surface roughness and ion release of these materials in different solutions were also studied. Titania and titanium showed similar push-out strengths at 1 and 3 months after implantation. This indicates that bone has a similar response to titanium and titania due to the similarity of the surface constitute. Titania-hydroxyapatite composite showed a significant increase in bonding strength at 1 and 3 months after implantation compared with titania. A gap, < 2 mum wide, was observed by SEM at the bone-TI interface while the bone-HA interface was fully mineralized. No release of titanium ions from titania (rutile) was detected in the solutions used, including 0.1 M HCl, whilst release of titanium ions from c.p.Ti was measured in 0.02 M lactic acid and 0.1 M HCl. The results suggested that a further oxidation of titanium may improve the stability of c.p.Ti and that titania-based material may be a strong biocompatible ceramic suitable for medical applications.
引用
收藏
页码:229 / 232
页数:4
相关论文
共 11 条
[1]  
BRANEMARK P I, 1969, Scandinavian Journal of Plastic and Reconstructive Surgery, V3, P81
[2]  
Dold J. M., 1990, ADV BIOMATER, P69
[3]  
ERICSON LE, 1990, ADV BIOMAT, V9, P333
[4]  
Forberg S., 1986, ADV CERAM, V20, P321
[5]  
JARCHO M, 1981, CLIN ORTHOP RELAT R, P259
[6]   EVALUATION OF THE MECHANICAL-PROPERTIES OF HOT ISOSTATICALLY PRESSED TITANIA AND TITANIA CALCIUM-PHOSPHATE COMPOSITES [J].
LI, J ;
FORBERG, S ;
HERMANSSON, L .
BIOMATERIALS, 1991, 12 (04) :438-440
[7]   THREADED VERSUS POROUS-SURFACED DESIGNS FOR IMPLANT STABILIZATION IN BONE-ENDODONTIC IMPLANT MODEL [J].
MANIATOPOULOS, C ;
PILLIAR, RM ;
SMITH, DC .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1986, 20 (09) :1309-1333
[8]  
MORONI A, 1990, BIOCERAMICS, V2, P125
[9]   AUGER-ELECTRON SPECTROSCOPIC STUDIES OF THE INTERFACE BETWEEN HUMAN-TISSUE AND IMPLANTS OF TITANIUM AND STAINLESS-STEEL [J].
SUNDGREN, JE ;
BODO, P ;
LUNDSTROM, I .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1986, 110 (01) :9-20
[10]  