AEROSOL INTERFACING EFFECTS ON DISCRETE SAMPLE INTRODUCTION COUPLED WITH SPECTROMETRIC DETECTION

被引:10
作者
KOROPCHAK, JA
ALLEN, L
DAVIS, JM
机构
关键词
DISCRETE SAMPLES; FLOW INJECTION; LIQUID CHROMATOGRAPHY; AEROSOL INTERFACING; BAND BROADENING; DISPERSION;
D O I
10.1366/0003702924125023
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Aerosol techniques are commonly employed to interface discrete sampling techniques (flow injection analysis and liquid chromatography) with various detectors. The effects of these interfaces on discrete signals have not been described, nor has a rationale been established for presumed differences in band broadening due to aerosol-phase extra-column volume, compared to liquid-phase extra-column volume. In this report, the effects of laminar flow through several transport geometries on signal recovery and band broadening for both wet and desolvated aerosols are investigated. Data presented for the conditions studied indicate that signal losses with linear systems are primarily affected by gravitational settling. Increases in residence time lead to larger losses. Centrifugal effects, which lead to higher losses with coiled systems at high linear velocities, however, appear to have a stabilizing effect at lower velocities. Desolvation significantly reduces the level of gravitational or centrifugal losses via reduction in particle sizes. Band broadening results primarily from convection within laminar flow systems. This result was established on the basis of comparison of real signals with those generated from a convolution routine which mimics the effects of convective dispersion within laminar flows. The relatively high flow rates of aerosol transport systems result in short residence times and small effects of large transport volumes on dispersion. Sample losses also appear to offset band broadening to some extent by reducing peak tailing. Conditions providing efficient analyte transport and signal recovery, as well as low dispersion, can be established.
引用
收藏
页码:682 / 689
页数:8
相关论文
共 27 条
[1]  
Bosworth R.C.L., 1948, PHILOS MAG, V39, P846
[2]  
BRACEWELL RN, 1988, FOURIER TRANSFORM IT, V4, P291
[3]  
BRACWELL RN, 1986, FOURIER TRANSFORM IT, P30
[4]   INTERFACING WITH AEROSOLS - CONCEPT, PLACE, AND TIME [J].
BROWNER, RF .
MICROCHEMICAL JOURNAL, 1989, 40 (01) :4-29
[5]   AEROSOL TRANSPORT MODEL FOR ATOMIC SPECTROMETRY [J].
BROWNER, RF ;
BOORN, AW ;
SMITH, DD .
ANALYTICAL CHEMISTRY, 1982, 54 (08) :1411-1419
[6]  
BROWNER RF, 1987, INDUCTIVELY COUPLED, pCH8
[7]  
BURGUERA JL, 1989, FLOW INJECTION ATOMI
[8]   2-NEBULIZER AUTOMATIC SYSTEM FOR SOLID-SURFACE ROOM-TEMPERATURE PHOSPHORESCENCE ANALYSIS [J].
CAMPIGLIA, AD ;
PERRY, LM ;
WINEFORDNER, JD .
APPLIED SPECTROSCOPY, 1990, 44 (04) :729-732
[9]  
CAMPIGLIA AD, 1990, J CHROMATOGR, V37, P508
[10]   EVAPORATIVE ANALYZER AS A MASS DETECTOR FOR LIQUID-CHROMATOGRAPHY [J].
CHARLESWORTH, JM .
ANALYTICAL CHEMISTRY, 1978, 50 (11) :1414-1420